Cargando…

The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays

Current software applications for densitometric analysis, such as ImageJ, QuantityOne (BioRad) and the Intelligent or Advanced Quantifier (Bio Image) do not allow to take the non-linearity of autoradiographic films into account during calibration. As a consequence, quantification of autoradiographs...

Descripción completa

Detalles Bibliográficos
Autores principales: van Oeffelen, Liesbeth, Peeters, Eveline, Nguyen Le Minh, Phu, Charlier, Daniël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3897411/
https://www.ncbi.nlm.nih.gov/pubmed/24465496
http://dx.doi.org/10.1371/journal.pone.0085146
_version_ 1782300228096884736
author van Oeffelen, Liesbeth
Peeters, Eveline
Nguyen Le Minh, Phu
Charlier, Daniël
author_facet van Oeffelen, Liesbeth
Peeters, Eveline
Nguyen Le Minh, Phu
Charlier, Daniël
author_sort van Oeffelen, Liesbeth
collection PubMed
description Current software applications for densitometric analysis, such as ImageJ, QuantityOne (BioRad) and the Intelligent or Advanced Quantifier (Bio Image) do not allow to take the non-linearity of autoradiographic films into account during calibration. As a consequence, quantification of autoradiographs is often regarded as problematic, and phosphorimaging is the preferred alternative. However, the non-linear behaviour of autoradiographs can be described mathematically, so it can be accounted for. Therefore, the ‘Densitometric Image Analysis Software’ has been developed, which allows to quantify electrophoretic bands in autoradiographs, as well as in gels and phosphorimages, while providing optimized band selection support to the user. Moreover, the program can determine protein-DNA binding constants from Electrophoretic Mobility Shift Assays (EMSAs). For this purpose, the software calculates a chosen stepwise equilibrium constant for each migration lane within the EMSA, and estimates the errors due to non-uniformity of the background noise, smear caused by complex dissociation or denaturation of double-stranded DNA, and technical errors such as pipetting inaccuracies. Thereby, the program helps the user to optimize experimental parameters and to choose the best lanes for estimating an average equilibrium constant. This process can reduce the inaccuracy of equilibrium constants from the usual factor of 2 to about 20%, which is particularly useful when determining position weight matrices and cooperative binding constants to predict genomic binding sites. The MATLAB source code, platform-dependent software and installation instructions are available via the website http://micr.vub.ac.be.
format Online
Article
Text
id pubmed-3897411
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38974112014-01-24 The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays van Oeffelen, Liesbeth Peeters, Eveline Nguyen Le Minh, Phu Charlier, Daniël PLoS One Research Article Current software applications for densitometric analysis, such as ImageJ, QuantityOne (BioRad) and the Intelligent or Advanced Quantifier (Bio Image) do not allow to take the non-linearity of autoradiographic films into account during calibration. As a consequence, quantification of autoradiographs is often regarded as problematic, and phosphorimaging is the preferred alternative. However, the non-linear behaviour of autoradiographs can be described mathematically, so it can be accounted for. Therefore, the ‘Densitometric Image Analysis Software’ has been developed, which allows to quantify electrophoretic bands in autoradiographs, as well as in gels and phosphorimages, while providing optimized band selection support to the user. Moreover, the program can determine protein-DNA binding constants from Electrophoretic Mobility Shift Assays (EMSAs). For this purpose, the software calculates a chosen stepwise equilibrium constant for each migration lane within the EMSA, and estimates the errors due to non-uniformity of the background noise, smear caused by complex dissociation or denaturation of double-stranded DNA, and technical errors such as pipetting inaccuracies. Thereby, the program helps the user to optimize experimental parameters and to choose the best lanes for estimating an average equilibrium constant. This process can reduce the inaccuracy of equilibrium constants from the usual factor of 2 to about 20%, which is particularly useful when determining position weight matrices and cooperative binding constants to predict genomic binding sites. The MATLAB source code, platform-dependent software and installation instructions are available via the website http://micr.vub.ac.be. Public Library of Science 2014-01-21 /pmc/articles/PMC3897411/ /pubmed/24465496 http://dx.doi.org/10.1371/journal.pone.0085146 Text en © 2014 van Oeffelen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
van Oeffelen, Liesbeth
Peeters, Eveline
Nguyen Le Minh, Phu
Charlier, Daniël
The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title_full The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title_fullStr The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title_full_unstemmed The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title_short The ‘Densitometric Image Analysis Software’ and Its Application to Determine Stepwise Equilibrium Constants from Electrophoretic Mobility Shift Assays
title_sort ‘densitometric image analysis software’ and its application to determine stepwise equilibrium constants from electrophoretic mobility shift assays
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3897411/
https://www.ncbi.nlm.nih.gov/pubmed/24465496
http://dx.doi.org/10.1371/journal.pone.0085146
work_keys_str_mv AT vanoeffelenliesbeth thedensitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT peeterseveline thedensitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT nguyenleminhphu thedensitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT charlierdaniel thedensitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT vanoeffelenliesbeth densitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT peeterseveline densitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT nguyenleminhphu densitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays
AT charlierdaniel densitometricimageanalysissoftwareanditsapplicationtodeterminestepwiseequilibriumconstantsfromelectrophoreticmobilityshiftassays