Which lipid measurement should we monitor? An analysis of the LIPID study

OBJECTIVES: To evaluate the optimal lipid to measure in monitoring patients, we assessed three factors that influence the choice of monitoring tests: (1) clinical validity; (2) responsiveness to therapy changes and (3) the size of the long-term ‘signal-to-noise’ ratio. DESIGN: Longitudinal analyses...