Cargando…

Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study

OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jae Hyeon, Kim, Ho-Geun, Oh, Byung-Mo, Lee, Min-Woo, Hwang, In-Kyeong, Lee, Shi-Uk, Han, Tai Ryoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Rehabilitation Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953370/
https://www.ncbi.nlm.nih.gov/pubmed/24639932
http://dx.doi.org/10.5535/arm.2014.38.1.94
_version_ 1782307341935312896
author Park, Jae Hyeon
Kim, Ho-Geun
Oh, Byung-Mo
Lee, Min-Woo
Hwang, In-Kyeong
Lee, Shi-Uk
Han, Tai Ryoon
author_facet Park, Jae Hyeon
Kim, Ho-Geun
Oh, Byung-Mo
Lee, Min-Woo
Hwang, In-Kyeong
Lee, Shi-Uk
Han, Tai Ryoon
author_sort Park, Jae Hyeon
collection PubMed
description OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid with various concentrations (range, GUA 1%-4%, XAN 1%-6%, STA 1%-7%, at intervals of 1%) was measured with a rotational viscometer with various shear rates (1.29 s(-1), 5.16 s(-1), 51.6 s(-1), and 103 s(-1)) at a temperature of 35℃, representing body temperature. The viscosity of STA showed time dependent alteration. So STA was excluded. Viscosities of GUA and XAN (range of concentration, GUA 1%-3%, XAN 1%-6%, at intervals of 1%) were measured at a room temperature of 20℃. LST was conducted to compare GUA and XAN (concentration, 1.5%, 2.0%, and 3.0%) at temperatures of 20℃ and 35℃. RESULTS: The viscosities of 1% GUA and XAN were similar. However, viscosity differences between GUA and XAN were gradually larger as concentration increased. The shear thinning effect, the inverse relationship between the viscosity and the shear rate, was more predominant in XAN than in GUA. The results of LST were not substantially different from GUA and XAN, in spite of the difference in viscosity. However manufacturers' instructions do not demonstrate the rheological properties of thickeners. CONCLUSION: The viscosities of thickened fluid were different when the measurement conditions changed. Any single measurement might not be sufficient to determine comparable viscosity with different thickeners. Clinical decision for the use of a specific thickener seems to necessitate cautious consideration of results from a viscometer, LST, and an expert's opinion.
format Online
Article
Text
id pubmed-3953370
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Korean Academy of Rehabilitation Medicine
record_format MEDLINE/PubMed
spelling pubmed-39533702014-03-17 Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study Park, Jae Hyeon Kim, Ho-Geun Oh, Byung-Mo Lee, Min-Woo Hwang, In-Kyeong Lee, Shi-Uk Han, Tai Ryoon Ann Rehabil Med Original Article OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid with various concentrations (range, GUA 1%-4%, XAN 1%-6%, STA 1%-7%, at intervals of 1%) was measured with a rotational viscometer with various shear rates (1.29 s(-1), 5.16 s(-1), 51.6 s(-1), and 103 s(-1)) at a temperature of 35℃, representing body temperature. The viscosity of STA showed time dependent alteration. So STA was excluded. Viscosities of GUA and XAN (range of concentration, GUA 1%-3%, XAN 1%-6%, at intervals of 1%) were measured at a room temperature of 20℃. LST was conducted to compare GUA and XAN (concentration, 1.5%, 2.0%, and 3.0%) at temperatures of 20℃ and 35℃. RESULTS: The viscosities of 1% GUA and XAN were similar. However, viscosity differences between GUA and XAN were gradually larger as concentration increased. The shear thinning effect, the inverse relationship between the viscosity and the shear rate, was more predominant in XAN than in GUA. The results of LST were not substantially different from GUA and XAN, in spite of the difference in viscosity. However manufacturers' instructions do not demonstrate the rheological properties of thickeners. CONCLUSION: The viscosities of thickened fluid were different when the measurement conditions changed. Any single measurement might not be sufficient to determine comparable viscosity with different thickeners. Clinical decision for the use of a specific thickener seems to necessitate cautious consideration of results from a viscometer, LST, and an expert's opinion. Korean Academy of Rehabilitation Medicine 2014-02 2014-02-25 /pmc/articles/PMC3953370/ /pubmed/24639932 http://dx.doi.org/10.5535/arm.2014.38.1.94 Text en Copyright © 2014 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Jae Hyeon
Kim, Ho-Geun
Oh, Byung-Mo
Lee, Min-Woo
Hwang, In-Kyeong
Lee, Shi-Uk
Han, Tai Ryoon
Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title_full Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title_fullStr Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title_full_unstemmed Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title_short Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
title_sort comparison of different gum-based thickeners using a viscometer and line spread test: a preliminary study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953370/
https://www.ncbi.nlm.nih.gov/pubmed/24639932
http://dx.doi.org/10.5535/arm.2014.38.1.94
work_keys_str_mv AT parkjaehyeon comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT kimhogeun comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT ohbyungmo comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT leeminwoo comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT hwanginkyeong comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT leeshiuk comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy
AT hantairyoon comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy