Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study
OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid wi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953370/ https://www.ncbi.nlm.nih.gov/pubmed/24639932 http://dx.doi.org/10.5535/arm.2014.38.1.94 |
_version_ | 1782307341935312896 |
---|---|
author | Park, Jae Hyeon Kim, Ho-Geun Oh, Byung-Mo Lee, Min-Woo Hwang, In-Kyeong Lee, Shi-Uk Han, Tai Ryoon |
author_facet | Park, Jae Hyeon Kim, Ho-Geun Oh, Byung-Mo Lee, Min-Woo Hwang, In-Kyeong Lee, Shi-Uk Han, Tai Ryoon |
author_sort | Park, Jae Hyeon |
collection | PubMed |
description | OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid with various concentrations (range, GUA 1%-4%, XAN 1%-6%, STA 1%-7%, at intervals of 1%) was measured with a rotational viscometer with various shear rates (1.29 s(-1), 5.16 s(-1), 51.6 s(-1), and 103 s(-1)) at a temperature of 35℃, representing body temperature. The viscosity of STA showed time dependent alteration. So STA was excluded. Viscosities of GUA and XAN (range of concentration, GUA 1%-3%, XAN 1%-6%, at intervals of 1%) were measured at a room temperature of 20℃. LST was conducted to compare GUA and XAN (concentration, 1.5%, 2.0%, and 3.0%) at temperatures of 20℃ and 35℃. RESULTS: The viscosities of 1% GUA and XAN were similar. However, viscosity differences between GUA and XAN were gradually larger as concentration increased. The shear thinning effect, the inverse relationship between the viscosity and the shear rate, was more predominant in XAN than in GUA. The results of LST were not substantially different from GUA and XAN, in spite of the difference in viscosity. However manufacturers' instructions do not demonstrate the rheological properties of thickeners. CONCLUSION: The viscosities of thickened fluid were different when the measurement conditions changed. Any single measurement might not be sufficient to determine comparable viscosity with different thickeners. Clinical decision for the use of a specific thickener seems to necessitate cautious consideration of results from a viscometer, LST, and an expert's opinion. |
format | Online Article Text |
id | pubmed-3953370 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-39533702014-03-17 Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study Park, Jae Hyeon Kim, Ho-Geun Oh, Byung-Mo Lee, Min-Woo Hwang, In-Kyeong Lee, Shi-Uk Han, Tai Ryoon Ann Rehabil Med Original Article OBJECTIVE: To compare fluid thickeners composed of starch polysaccharide (STA), guar gum-based polysaccharide (GUA), and xanthan gum-based polysaccharide (XAN) with the use of a viscometer and a line spread test (LST) under various measurement conditions. METHODS: The viscosity of thickened fluid with various concentrations (range, GUA 1%-4%, XAN 1%-6%, STA 1%-7%, at intervals of 1%) was measured with a rotational viscometer with various shear rates (1.29 s(-1), 5.16 s(-1), 51.6 s(-1), and 103 s(-1)) at a temperature of 35℃, representing body temperature. The viscosity of STA showed time dependent alteration. So STA was excluded. Viscosities of GUA and XAN (range of concentration, GUA 1%-3%, XAN 1%-6%, at intervals of 1%) were measured at a room temperature of 20℃. LST was conducted to compare GUA and XAN (concentration, 1.5%, 2.0%, and 3.0%) at temperatures of 20℃ and 35℃. RESULTS: The viscosities of 1% GUA and XAN were similar. However, viscosity differences between GUA and XAN were gradually larger as concentration increased. The shear thinning effect, the inverse relationship between the viscosity and the shear rate, was more predominant in XAN than in GUA. The results of LST were not substantially different from GUA and XAN, in spite of the difference in viscosity. However manufacturers' instructions do not demonstrate the rheological properties of thickeners. CONCLUSION: The viscosities of thickened fluid were different when the measurement conditions changed. Any single measurement might not be sufficient to determine comparable viscosity with different thickeners. Clinical decision for the use of a specific thickener seems to necessitate cautious consideration of results from a viscometer, LST, and an expert's opinion. Korean Academy of Rehabilitation Medicine 2014-02 2014-02-25 /pmc/articles/PMC3953370/ /pubmed/24639932 http://dx.doi.org/10.5535/arm.2014.38.1.94 Text en Copyright © 2014 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Jae Hyeon Kim, Ho-Geun Oh, Byung-Mo Lee, Min-Woo Hwang, In-Kyeong Lee, Shi-Uk Han, Tai Ryoon Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title | Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title_full | Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title_fullStr | Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title_full_unstemmed | Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title_short | Comparison of Different Gum-Based Thickeners Using a Viscometer and Line Spread Test: A Preliminary Study |
title_sort | comparison of different gum-based thickeners using a viscometer and line spread test: a preliminary study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3953370/ https://www.ncbi.nlm.nih.gov/pubmed/24639932 http://dx.doi.org/10.5535/arm.2014.38.1.94 |
work_keys_str_mv | AT parkjaehyeon comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT kimhogeun comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT ohbyungmo comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT leeminwoo comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT hwanginkyeong comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT leeshiuk comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy AT hantairyoon comparisonofdifferentgumbasedthickenersusingaviscometerandlinespreadtestapreliminarystudy |