Cargando…

Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander

BACKGROUND AND OBJECTIVES: Increased vascular wall shear stress by elevated plasma viscosity significantly enhances the endothelial nitric oxide synthase (eNOS) activity during an acute isovolemic hemodilution. Also the modulation of plasma viscosity has effects on the cardiac function that were rev...

Descripción completa

Detalles Bibliográficos
Autores principales: Chatpun, Surapong, Cabrales, Pedro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958604/
https://www.ncbi.nlm.nih.gov/pubmed/24653740
http://dx.doi.org/10.4070/kcj.2014.44.2.105
_version_ 1782307903372263424
author Chatpun, Surapong
Cabrales, Pedro
author_facet Chatpun, Surapong
Cabrales, Pedro
author_sort Chatpun, Surapong
collection PubMed
description BACKGROUND AND OBJECTIVES: Increased vascular wall shear stress by elevated plasma viscosity significantly enhances the endothelial nitric oxide synthase (eNOS) activity during an acute isovolemic hemodilution. Also the modulation of plasma viscosity has effects on the cardiac function that were revealed if a left ventricular (LV) pressure-volume (PV) measurement was used. The aim of this study was to assess cardiac function responses to nitric oxide synthase (NOS) inhibitors with the presence of an elevated plasma viscosity but a low hematocrit level. Furthermore, systemic parameters were monitored in a murine model. MATERIALS AND METHODS: As test group five anesthetized hamsters were administered with N(G)-nitro-L-arginine methyl ester (L-NAME), NOS inhibitor, whereas five other hamsters were used as control group without L-NAME infusion. The dosage of L-NAME was 10 mg/kg. An isovolemic hemodilution was performed by 40% of estimated blood volume with 6% w/v dextran 2000 kDa, high viscosity plasma expanders (PEs) with viscosity 6.34 cP. LV function was measured and assessed using a 1.4 Fr PV conductance catheter. RESULTS: The study results demonstrated that NOS inhibition prevented the normal cardiac adaptive response after hemodilution. The endsystolic pressure increased 14% after L-NAME infusion and maintained higher than at the baseline after hemodilution, whereas it gradually decreased in the animals without L-NAME infusion. The admission of L-NAME significantly decreased the maximum rate of ventricular pressure rise (+dP/dt(max)), stroke volume and cardiac output after hemodilution if compared to the control group (p<0.05). CONCLUSION: This finding supports the presumption that nitric oxide induced by an increased plasma viscosity with the use of a high viscosity PE plays a major role in the cardiac function during an acute isovolemic hemodilution.
format Online
Article
Text
id pubmed-3958604
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-39586042014-03-20 Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander Chatpun, Surapong Cabrales, Pedro Korean Circ J Original Article BACKGROUND AND OBJECTIVES: Increased vascular wall shear stress by elevated plasma viscosity significantly enhances the endothelial nitric oxide synthase (eNOS) activity during an acute isovolemic hemodilution. Also the modulation of plasma viscosity has effects on the cardiac function that were revealed if a left ventricular (LV) pressure-volume (PV) measurement was used. The aim of this study was to assess cardiac function responses to nitric oxide synthase (NOS) inhibitors with the presence of an elevated plasma viscosity but a low hematocrit level. Furthermore, systemic parameters were monitored in a murine model. MATERIALS AND METHODS: As test group five anesthetized hamsters were administered with N(G)-nitro-L-arginine methyl ester (L-NAME), NOS inhibitor, whereas five other hamsters were used as control group without L-NAME infusion. The dosage of L-NAME was 10 mg/kg. An isovolemic hemodilution was performed by 40% of estimated blood volume with 6% w/v dextran 2000 kDa, high viscosity plasma expanders (PEs) with viscosity 6.34 cP. LV function was measured and assessed using a 1.4 Fr PV conductance catheter. RESULTS: The study results demonstrated that NOS inhibition prevented the normal cardiac adaptive response after hemodilution. The endsystolic pressure increased 14% after L-NAME infusion and maintained higher than at the baseline after hemodilution, whereas it gradually decreased in the animals without L-NAME infusion. The admission of L-NAME significantly decreased the maximum rate of ventricular pressure rise (+dP/dt(max)), stroke volume and cardiac output after hemodilution if compared to the control group (p<0.05). CONCLUSION: This finding supports the presumption that nitric oxide induced by an increased plasma viscosity with the use of a high viscosity PE plays a major role in the cardiac function during an acute isovolemic hemodilution. The Korean Society of Cardiology 2014-03 2014-03-12 /pmc/articles/PMC3958604/ /pubmed/24653740 http://dx.doi.org/10.4070/kcj.2014.44.2.105 Text en Copyright © 2014 The Korean Society of Cardiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chatpun, Surapong
Cabrales, Pedro
Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title_full Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title_fullStr Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title_full_unstemmed Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title_short Nitric Oxide Synthase Inhibition Attenuates Cardiac Response to Hemodilution with Viscogenic Plasma Expander
title_sort nitric oxide synthase inhibition attenuates cardiac response to hemodilution with viscogenic plasma expander
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3958604/
https://www.ncbi.nlm.nih.gov/pubmed/24653740
http://dx.doi.org/10.4070/kcj.2014.44.2.105
work_keys_str_mv AT chatpunsurapong nitricoxidesynthaseinhibitionattenuatescardiacresponsetohemodilutionwithviscogenicplasmaexpander
AT cabralespedro nitricoxidesynthaseinhibitionattenuatescardiacresponsetohemodilutionwithviscogenicplasmaexpander