Comparison between C1–2 Fixation with and without Supplemental Posterior Wiring

Study Design Retrospective analysis. Clinical Question Is there a difference between the screw–rod construct (SRC) procedure without wiring and the SRC procedure with wiring with respect to fusion, implant failure, reoperation, donor-site morbidity, and complication rates? Patients and Methods We pe...