BACKGROUND: AZD3514 inhibits and down regulates the androgen receptor (AR) and has undergone clinical trials in prostate cancer. To provide proof-of-mechanism (POM) in patients, an immunohistochemistry (IHC) method for determination of AR in circulating tumour cells (CTC) was developed and validated...

Descripción completa

Detalles Bibliográficos
Autores principales: Cummings, Jeffrey, Sloane, Robert, Morris, Karen, Zhou, Cong, Lancashire, Matt, Moore, David, Elliot, Tony, Clarke, Noel, Dive, Caroline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3977890/
https://www.ncbi.nlm.nih.gov/pubmed/24674711
http://dx.doi.org/10.1186/1471-2407-14-226
Descripción
Sumario:BACKGROUND: AZD3514 inhibits and down regulates the androgen receptor (AR) and has undergone clinical trials in prostate cancer. To provide proof-of-mechanism (POM) in patients, an immunohistochemistry (IHC) method for determination of AR in circulating tumour cells (CTC) was developed and validated. METHODS: After an assessment of specificity validation focused on intra- and inter-operator reproducibility utilising a novel modification of incurred sample reanalysis (ISR). β-Content γ-confidence tolerance intervals (BCTI) and Cohen’s Kappa (κ) were employed in statistical analysis of results. RESULTS: In a first set of IHC reproducibility experiments, almost perfect agreement was recorded (κ=0.94) when two different operators scored CTC as overall positive or negative for AR. However, BCTI analysis identified a specific bias in scoring staining intensity, where one operator favoured moderate over strong assignments, whereas the reverse was the case with the second operator. After a period of additional training involving deployment of a panel of standardised images, a second set of validation experiments were conducted. These showed correction of the inter-operator bias by BCTI with κ for scoring intensity increasing from 0.59 to 0.81, indicative of almost perfect agreement. CONCLUSIONS: By application of BCTI to the validation of IHC, operator bias and therefore poor reproducibility can be identified, characterised and corrected to achieve a level of error normally associated with a quantitative biomarker assay, such as an ELISA. The methodological approach described herein can be applied to any generic IHC technique.