Cargando…
Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We devel...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000192/ https://www.ncbi.nlm.nih.gov/pubmed/24769870 http://dx.doi.org/10.1371/journal.pone.0096420 |
_version_ | 1782313593155354624 |
---|---|
author | Song, Najie Zhong, Xueting Li, Qingge |
author_facet | Song, Najie Zhong, Xueting Li, Qingge |
author_sort | Song, Najie |
collection | PubMed |
description | Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We developed real-time bidirectional pyrophosphorolysis-activated polymerization (real-time Bi-PAP) that allows quantitative detection of somatic mutations. We applied the method to quantify seven mutations at codons 12 and 13 in KRAS, and 2 mutations (L858R, and T790M) in EGFR in clinical samples. The real-time Bi-PAP could detect 0.01% mutation in the presence of 100 ng template DNA. Of the 34 samples from the colon cancer patients, real-time Bi-PAP detected 14 KRAS mutant samples whereas the traditional real-time allele-specific PCR missed two samples with mutation abundance <1% and DNA sequencing missed nine samples with mutation abundance <10%. The detection results of the two EGFR mutations in 45 non-small cell lung cancer samples further supported the applicability of the real-time Bi-PAP. The real-time Bi-PAP also proved to be more efficient than the real-time allele-specific PCR in the detection of templates prepared from formalin-fixed paraffin-embedded samples. Thus, real-time Bi-PAP can be used for rapid and accurate quantification of somatic mutations. This flexible approach could be widely used for somatic mutation detection in clinical settings. |
format | Online Article Text |
id | pubmed-4000192 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-40001922014-04-29 Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations Song, Najie Zhong, Xueting Li, Qingge PLoS One Research Article Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We developed real-time bidirectional pyrophosphorolysis-activated polymerization (real-time Bi-PAP) that allows quantitative detection of somatic mutations. We applied the method to quantify seven mutations at codons 12 and 13 in KRAS, and 2 mutations (L858R, and T790M) in EGFR in clinical samples. The real-time Bi-PAP could detect 0.01% mutation in the presence of 100 ng template DNA. Of the 34 samples from the colon cancer patients, real-time Bi-PAP detected 14 KRAS mutant samples whereas the traditional real-time allele-specific PCR missed two samples with mutation abundance <1% and DNA sequencing missed nine samples with mutation abundance <10%. The detection results of the two EGFR mutations in 45 non-small cell lung cancer samples further supported the applicability of the real-time Bi-PAP. The real-time Bi-PAP also proved to be more efficient than the real-time allele-specific PCR in the detection of templates prepared from formalin-fixed paraffin-embedded samples. Thus, real-time Bi-PAP can be used for rapid and accurate quantification of somatic mutations. This flexible approach could be widely used for somatic mutation detection in clinical settings. Public Library of Science 2014-04-25 /pmc/articles/PMC4000192/ /pubmed/24769870 http://dx.doi.org/10.1371/journal.pone.0096420 Text en © 2014 Song et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Song, Najie Zhong, Xueting Li, Qingge Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title | Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title_full | Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title_fullStr | Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title_full_unstemmed | Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title_short | Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations |
title_sort | real-time bidirectional pyrophosphorolysis-activated polymerization for quantitative detection of somatic mutations |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000192/ https://www.ncbi.nlm.nih.gov/pubmed/24769870 http://dx.doi.org/10.1371/journal.pone.0096420 |
work_keys_str_mv | AT songnajie realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations AT zhongxueting realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations AT liqingge realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations |