Cargando…

Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations

Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We devel...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Najie, Zhong, Xueting, Li, Qingge
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000192/
https://www.ncbi.nlm.nih.gov/pubmed/24769870
http://dx.doi.org/10.1371/journal.pone.0096420
_version_ 1782313593155354624
author Song, Najie
Zhong, Xueting
Li, Qingge
author_facet Song, Najie
Zhong, Xueting
Li, Qingge
author_sort Song, Najie
collection PubMed
description Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We developed real-time bidirectional pyrophosphorolysis-activated polymerization (real-time Bi-PAP) that allows quantitative detection of somatic mutations. We applied the method to quantify seven mutations at codons 12 and 13 in KRAS, and 2 mutations (L858R, and T790M) in EGFR in clinical samples. The real-time Bi-PAP could detect 0.01% mutation in the presence of 100 ng template DNA. Of the 34 samples from the colon cancer patients, real-time Bi-PAP detected 14 KRAS mutant samples whereas the traditional real-time allele-specific PCR missed two samples with mutation abundance <1% and DNA sequencing missed nine samples with mutation abundance <10%. The detection results of the two EGFR mutations in 45 non-small cell lung cancer samples further supported the applicability of the real-time Bi-PAP. The real-time Bi-PAP also proved to be more efficient than the real-time allele-specific PCR in the detection of templates prepared from formalin-fixed paraffin-embedded samples. Thus, real-time Bi-PAP can be used for rapid and accurate quantification of somatic mutations. This flexible approach could be widely used for somatic mutation detection in clinical settings.
format Online
Article
Text
id pubmed-4000192
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-40001922014-04-29 Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations Song, Najie Zhong, Xueting Li, Qingge PLoS One Research Article Detection of somatic mutations for targeted therapy is increasingly used in clinical settings. However, due to the difficulties of detecting rare mutations in excess of wild-type DNA, current methods often lack high sensitivity, require multiple procedural steps, or fail to be quantitative. We developed real-time bidirectional pyrophosphorolysis-activated polymerization (real-time Bi-PAP) that allows quantitative detection of somatic mutations. We applied the method to quantify seven mutations at codons 12 and 13 in KRAS, and 2 mutations (L858R, and T790M) in EGFR in clinical samples. The real-time Bi-PAP could detect 0.01% mutation in the presence of 100 ng template DNA. Of the 34 samples from the colon cancer patients, real-time Bi-PAP detected 14 KRAS mutant samples whereas the traditional real-time allele-specific PCR missed two samples with mutation abundance <1% and DNA sequencing missed nine samples with mutation abundance <10%. The detection results of the two EGFR mutations in 45 non-small cell lung cancer samples further supported the applicability of the real-time Bi-PAP. The real-time Bi-PAP also proved to be more efficient than the real-time allele-specific PCR in the detection of templates prepared from formalin-fixed paraffin-embedded samples. Thus, real-time Bi-PAP can be used for rapid and accurate quantification of somatic mutations. This flexible approach could be widely used for somatic mutation detection in clinical settings. Public Library of Science 2014-04-25 /pmc/articles/PMC4000192/ /pubmed/24769870 http://dx.doi.org/10.1371/journal.pone.0096420 Text en © 2014 Song et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Song, Najie
Zhong, Xueting
Li, Qingge
Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title_full Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title_fullStr Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title_full_unstemmed Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title_short Real-Time Bidirectional Pyrophosphorolysis-Activated Polymerization for Quantitative Detection of Somatic Mutations
title_sort real-time bidirectional pyrophosphorolysis-activated polymerization for quantitative detection of somatic mutations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000192/
https://www.ncbi.nlm.nih.gov/pubmed/24769870
http://dx.doi.org/10.1371/journal.pone.0096420
work_keys_str_mv AT songnajie realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations
AT zhongxueting realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations
AT liqingge realtimebidirectionalpyrophosphorolysisactivatedpolymerizationforquantitativedetectionofsomaticmutations