Cargando…

Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications

The adherence of Platinum thin film on Si/SiO(2) wafer was studies using Chromium, Titanium or Alumina (Cr, Ti, Al(2)O(3)) as interlayer. The adhesion of Pt is a fundamental property in different areas, for example in MEMS devices, which operate at high temperature conditions, as well as in biomedic...

Descripción completa

Detalles Bibliográficos
Autores principales: Guarnieri, Vittorio, Biazi, Leonardo, Marchiori, Roberto, Lago, Alexandre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Landes Bioscience 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122564/
https://www.ncbi.nlm.nih.gov/pubmed/24743057
http://dx.doi.org/10.4161/biom.28822
_version_ 1782329371870101504
author Guarnieri, Vittorio
Biazi, Leonardo
Marchiori, Roberto
Lago, Alexandre
author_facet Guarnieri, Vittorio
Biazi, Leonardo
Marchiori, Roberto
Lago, Alexandre
author_sort Guarnieri, Vittorio
collection PubMed
description The adherence of Platinum thin film on Si/SiO(2) wafer was studies using Chromium, Titanium or Alumina (Cr, Ti, Al(2)O(3)) as interlayer. The adhesion of Pt is a fundamental property in different areas, for example in MEMS devices, which operate at high temperature conditions, as well as in biomedical applications, where the problem of adhesion of a Pt film to the substrate is known as a major challenge in several industrial applications health and in biomedical devices, such as for example in the stents.(1)(-)(4) We investigated the properties of Chromium, Titanium, and Alumina (Cr, Ti, and Al(2)O(3)) used as adhesion layers of Platinum (Pt) electrode. Thin films of Chromium, Titanium and Alumina were deposited on Silicon/Silicon dioxide (Si/SiO(2)) wafer by electron beam. We introduced Al(2)O(3) as a new adhesion layer to test the behavior of the Pt film at higher temperature using a ceramic adhesion thin film. Electric behaviors were measured for different annealing temperatures to know the performance for Cr/Pt, Ti/Pt, and Al(2)O(3)/Pt metallic film in the gas sensor application. All these metal layers showed a good adhesion onto Si/SiO(2) and also good Au wire bondability at room temperature, but for higher temperature than 400 °C the thin Cr/Pt and Ti/Pt films showed poor adhesion due to the atomic inter-diffusion between Platinum and the metal adhesion layers.(5) The proposed Al(2)O(3)/Pt ceramic-metal layers confirmed a better adherence for the higher temperatures tested.
format Online
Article
Text
id pubmed-4122564
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Landes Bioscience
record_format MEDLINE/PubMed
spelling pubmed-41225642015-04-17 Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications Guarnieri, Vittorio Biazi, Leonardo Marchiori, Roberto Lago, Alexandre Biomatter Report The adherence of Platinum thin film on Si/SiO(2) wafer was studies using Chromium, Titanium or Alumina (Cr, Ti, Al(2)O(3)) as interlayer. The adhesion of Pt is a fundamental property in different areas, for example in MEMS devices, which operate at high temperature conditions, as well as in biomedical applications, where the problem of adhesion of a Pt film to the substrate is known as a major challenge in several industrial applications health and in biomedical devices, such as for example in the stents.(1)(-)(4) We investigated the properties of Chromium, Titanium, and Alumina (Cr, Ti, and Al(2)O(3)) used as adhesion layers of Platinum (Pt) electrode. Thin films of Chromium, Titanium and Alumina were deposited on Silicon/Silicon dioxide (Si/SiO(2)) wafer by electron beam. We introduced Al(2)O(3) as a new adhesion layer to test the behavior of the Pt film at higher temperature using a ceramic adhesion thin film. Electric behaviors were measured for different annealing temperatures to know the performance for Cr/Pt, Ti/Pt, and Al(2)O(3)/Pt metallic film in the gas sensor application. All these metal layers showed a good adhesion onto Si/SiO(2) and also good Au wire bondability at room temperature, but for higher temperature than 400 °C the thin Cr/Pt and Ti/Pt films showed poor adhesion due to the atomic inter-diffusion between Platinum and the metal adhesion layers.(5) The proposed Al(2)O(3)/Pt ceramic-metal layers confirmed a better adherence for the higher temperatures tested. Landes Bioscience 2014-04-17 /pmc/articles/PMC4122564/ /pubmed/24743057 http://dx.doi.org/10.4161/biom.28822 Text en Copyright © 2014 Landes Bioscience http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Report
Guarnieri, Vittorio
Biazi, Leonardo
Marchiori, Roberto
Lago, Alexandre
Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title_full Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title_fullStr Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title_full_unstemmed Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title_short Platinum metallization for MEMS application: Focus on coating adhesion for biomedical applications
title_sort platinum metallization for mems application: focus on coating adhesion for biomedical applications
topic Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4122564/
https://www.ncbi.nlm.nih.gov/pubmed/24743057
http://dx.doi.org/10.4161/biom.28822
work_keys_str_mv AT guarnierivittorio platinummetallizationformemsapplicationfocusoncoatingadhesionforbiomedicalapplications
AT biazileonardo platinummetallizationformemsapplicationfocusoncoatingadhesionforbiomedicalapplications
AT marchioriroberto platinummetallizationformemsapplicationfocusoncoatingadhesionforbiomedicalapplications
AT lagoalexandre platinummetallizationformemsapplicationfocusoncoatingadhesionforbiomedicalapplications