Cargando…

Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency

The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruijter, Jan M., Lorenz, Peter, Tuomi, Jari M., Hecker, Michael, van den Hoff, Maurice J. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167442/
https://www.ncbi.nlm.nih.gov/pubmed/25253910
http://dx.doi.org/10.1007/s00604-013-1155-8
_version_ 1782335421065199616
author Ruijter, Jan M.
Lorenz, Peter
Tuomi, Jari M.
Hecker, Michael
van den Hoff, Maurice J. B.
author_facet Ruijter, Jan M.
Lorenz, Peter
Tuomi, Jari M.
Hecker, Michael
van den Hoff, Maurice J. B.
author_sort Ruijter, Jan M.
collection PubMed
description The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be categorized into six groups: (A) DNA-binding dyes; (B) hybridization probes; (C) hydrolysis probes; (D) LUX primers; (E) hairpin primers; and (F) the QZyme system. We have determined the kinetics of the increase in fluorescence for each of these groups with respect to the input of both ds-DNA and ss-cDNA. For the latter, we also evaluated mRNA and cDNA targeting probes or primers. This analysis revealed three situations. Hydrolysis probes and LUX primers, compared to DNA-binding dyes, do not require a correction of the observed quantification cycle. Hybridization probes and hairpin primers require a correction of −1 cycle (dubbed C-lag), while the QZyme system requires the C-lag correction and an efficiency-dependent C-shift correction. A PCR efficiency value can be derived from the relative increase in fluorescence in the exponential phase of the amplification curve for all monitoring chemistries. In case of hydrolysis probes, LUX primers and hairpin primers, however, this should be performed after cycle 12, and for the QZyme system after cycle 19, to keep the overestimation of the PCR efficiency below 0.5 %. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00604-013-1155-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4167442
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-41674422014-09-22 Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency Ruijter, Jan M. Lorenz, Peter Tuomi, Jari M. Hecker, Michael van den Hoff, Maurice J. B. Mikrochim Acta Original Paper The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be categorized into six groups: (A) DNA-binding dyes; (B) hybridization probes; (C) hydrolysis probes; (D) LUX primers; (E) hairpin primers; and (F) the QZyme system. We have determined the kinetics of the increase in fluorescence for each of these groups with respect to the input of both ds-DNA and ss-cDNA. For the latter, we also evaluated mRNA and cDNA targeting probes or primers. This analysis revealed three situations. Hydrolysis probes and LUX primers, compared to DNA-binding dyes, do not require a correction of the observed quantification cycle. Hybridization probes and hairpin primers require a correction of −1 cycle (dubbed C-lag), while the QZyme system requires the C-lag correction and an efficiency-dependent C-shift correction. A PCR efficiency value can be derived from the relative increase in fluorescence in the exponential phase of the amplification curve for all monitoring chemistries. In case of hydrolysis probes, LUX primers and hairpin primers, however, this should be performed after cycle 12, and for the QZyme system after cycle 19, to keep the overestimation of the PCR efficiency below 0.5 %. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00604-013-1155-8) contains supplementary material, which is available to authorized users. Springer Vienna 2014-01-14 2014 /pmc/articles/PMC4167442/ /pubmed/25253910 http://dx.doi.org/10.1007/s00604-013-1155-8 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Paper
Ruijter, Jan M.
Lorenz, Peter
Tuomi, Jari M.
Hecker, Michael
van den Hoff, Maurice J. B.
Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title_full Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title_fullStr Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title_full_unstemmed Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title_short Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
title_sort fluorescent-increase kinetics of different fluorescent reporters used for qpcr depend on monitoring chemistry, targeted sequence, type of dna input and pcr efficiency
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167442/
https://www.ncbi.nlm.nih.gov/pubmed/25253910
http://dx.doi.org/10.1007/s00604-013-1155-8
work_keys_str_mv AT ruijterjanm fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency
AT lorenzpeter fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency
AT tuomijarim fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency
AT heckermichael fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency
AT vandenhoffmauricejb fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency