Cargando…
Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency
The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167442/ https://www.ncbi.nlm.nih.gov/pubmed/25253910 http://dx.doi.org/10.1007/s00604-013-1155-8 |
_version_ | 1782335421065199616 |
---|---|
author | Ruijter, Jan M. Lorenz, Peter Tuomi, Jari M. Hecker, Michael van den Hoff, Maurice J. B. |
author_facet | Ruijter, Jan M. Lorenz, Peter Tuomi, Jari M. Hecker, Michael van den Hoff, Maurice J. B. |
author_sort | Ruijter, Jan M. |
collection | PubMed |
description | The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be categorized into six groups: (A) DNA-binding dyes; (B) hybridization probes; (C) hydrolysis probes; (D) LUX primers; (E) hairpin primers; and (F) the QZyme system. We have determined the kinetics of the increase in fluorescence for each of these groups with respect to the input of both ds-DNA and ss-cDNA. For the latter, we also evaluated mRNA and cDNA targeting probes or primers. This analysis revealed three situations. Hydrolysis probes and LUX primers, compared to DNA-binding dyes, do not require a correction of the observed quantification cycle. Hybridization probes and hairpin primers require a correction of −1 cycle (dubbed C-lag), while the QZyme system requires the C-lag correction and an efficiency-dependent C-shift correction. A PCR efficiency value can be derived from the relative increase in fluorescence in the exponential phase of the amplification curve for all monitoring chemistries. In case of hydrolysis probes, LUX primers and hairpin primers, however, this should be performed after cycle 12, and for the QZyme system after cycle 19, to keep the overestimation of the PCR efficiency below 0.5 %. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00604-013-1155-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4167442 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-41674422014-09-22 Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency Ruijter, Jan M. Lorenz, Peter Tuomi, Jari M. Hecker, Michael van den Hoff, Maurice J. B. Mikrochim Acta Original Paper The analysis of quantitative PCR data usually does not take into account the fact that the increase in fluorescence depends on the monitoring chemistry, the input of ds-DNA or ss-cDNA, and the directionality of the targeting of probes or primers. The monitoring chemistries currently available can be categorized into six groups: (A) DNA-binding dyes; (B) hybridization probes; (C) hydrolysis probes; (D) LUX primers; (E) hairpin primers; and (F) the QZyme system. We have determined the kinetics of the increase in fluorescence for each of these groups with respect to the input of both ds-DNA and ss-cDNA. For the latter, we also evaluated mRNA and cDNA targeting probes or primers. This analysis revealed three situations. Hydrolysis probes and LUX primers, compared to DNA-binding dyes, do not require a correction of the observed quantification cycle. Hybridization probes and hairpin primers require a correction of −1 cycle (dubbed C-lag), while the QZyme system requires the C-lag correction and an efficiency-dependent C-shift correction. A PCR efficiency value can be derived from the relative increase in fluorescence in the exponential phase of the amplification curve for all monitoring chemistries. In case of hydrolysis probes, LUX primers and hairpin primers, however, this should be performed after cycle 12, and for the QZyme system after cycle 19, to keep the overestimation of the PCR efficiency below 0.5 %. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00604-013-1155-8) contains supplementary material, which is available to authorized users. Springer Vienna 2014-01-14 2014 /pmc/articles/PMC4167442/ /pubmed/25253910 http://dx.doi.org/10.1007/s00604-013-1155-8 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Paper Ruijter, Jan M. Lorenz, Peter Tuomi, Jari M. Hecker, Michael van den Hoff, Maurice J. B. Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title | Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title_full | Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title_fullStr | Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title_full_unstemmed | Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title_short | Fluorescent-increase kinetics of different fluorescent reporters used for qPCR depend on monitoring chemistry, targeted sequence, type of DNA input and PCR efficiency |
title_sort | fluorescent-increase kinetics of different fluorescent reporters used for qpcr depend on monitoring chemistry, targeted sequence, type of dna input and pcr efficiency |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4167442/ https://www.ncbi.nlm.nih.gov/pubmed/25253910 http://dx.doi.org/10.1007/s00604-013-1155-8 |
work_keys_str_mv | AT ruijterjanm fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency AT lorenzpeter fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency AT tuomijarim fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency AT heckermichael fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency AT vandenhoffmauricejb fluorescentincreasekineticsofdifferentfluorescentreportersusedforqpcrdependonmonitoringchemistrytargetedsequencetypeofdnainputandpcrefficiency |