Mechanical Leeching with Venocutaneous Fistula and Monitoring with Near-infrared Spectroscopy
SUMMARY: The report herein describes the use of a venocutaneous fistula with angiocatheter attachment and near-infrared spectroscopy device to correct venous congestion of a vertical upper gracilis free flap used for breast reconstruction. This method of mechanical leeching was precisely controlled...