Cargando…

Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry

We detail here a protocol using tandem-tagged mCherry-EGFP-LC3 (C-G-LC3) to quantify autophagic flux in single cells by ratiometric flow cytometry and to isolate subpopulations of cells based on their relative levels of autophagic flux. This robust and sensitive method measures autophagic flux rathe...

Descripción completa

Detalles Bibliográficos
Autores principales: Gump, Jacob M, Thorburn, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Landes Bioscience 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203556/
https://www.ncbi.nlm.nih.gov/pubmed/24915460
http://dx.doi.org/10.4161/auto.29394
_version_ 1782340409717948416
author Gump, Jacob M
Thorburn, Andrew
author_facet Gump, Jacob M
Thorburn, Andrew
author_sort Gump, Jacob M
collection PubMed
description We detail here a protocol using tandem-tagged mCherry-EGFP-LC3 (C-G-LC3) to quantify autophagic flux in single cells by ratiometric flow cytometry and to isolate subpopulations of cells based on their relative levels of autophagic flux. This robust and sensitive method measures autophagic flux rather than autophagosome number and is an important addition to the autophagy researcher’s array of tools for measuring autophagy. Two crucial steps in this protocol are i) generate cells constitutively expressing C-G-LC3 with low to medium fluorescence and low fluorescence variability, and ii) correctly set up gates and voltage/gain on a properly equipped flow cytometer. We have used this method to measure autophagic flux in a variety of cell types and experimental systems using many different autophagy stimuli. On a sorting flow cytometer, this technique can be used to isolate cells with different levels of basal autophagic flux, or cells with variable induction of flux in response to a given stimulus for further analysis or experimentation. We have also combined quantification of autophagic flux with methods to measure apoptosis and cell surface proteins, demonstrating the usefulness of this protocol in combination with other flow cytometry labels and markers.
format Online
Article
Text
id pubmed-4203556
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Landes Bioscience
record_format MEDLINE/PubMed
spelling pubmed-42035562015-07-01 Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry Gump, Jacob M Thorburn, Andrew Autophagy Protocol We detail here a protocol using tandem-tagged mCherry-EGFP-LC3 (C-G-LC3) to quantify autophagic flux in single cells by ratiometric flow cytometry and to isolate subpopulations of cells based on their relative levels of autophagic flux. This robust and sensitive method measures autophagic flux rather than autophagosome number and is an important addition to the autophagy researcher’s array of tools for measuring autophagy. Two crucial steps in this protocol are i) generate cells constitutively expressing C-G-LC3 with low to medium fluorescence and low fluorescence variability, and ii) correctly set up gates and voltage/gain on a properly equipped flow cytometer. We have used this method to measure autophagic flux in a variety of cell types and experimental systems using many different autophagy stimuli. On a sorting flow cytometer, this technique can be used to isolate cells with different levels of basal autophagic flux, or cells with variable induction of flux in response to a given stimulus for further analysis or experimentation. We have also combined quantification of autophagic flux with methods to measure apoptosis and cell surface proteins, demonstrating the usefulness of this protocol in combination with other flow cytometry labels and markers. Landes Bioscience 2014-07-01 2014-06-05 /pmc/articles/PMC4203556/ /pubmed/24915460 http://dx.doi.org/10.4161/auto.29394 Text en Copyright © 2014 Landes Bioscience http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Protocol
Gump, Jacob M
Thorburn, Andrew
Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title_full Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title_fullStr Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title_full_unstemmed Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title_short Sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
title_sort sorting cells for basal and induced autophagic flux by quantitative ratiometric flow cytometry
topic Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203556/
https://www.ncbi.nlm.nih.gov/pubmed/24915460
http://dx.doi.org/10.4161/auto.29394
work_keys_str_mv AT gumpjacobm sortingcellsforbasalandinducedautophagicfluxbyquantitativeratiometricflowcytometry
AT thorburnandrew sortingcellsforbasalandinducedautophagicfluxbyquantitativeratiometricflowcytometry