Cargando…

Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides

Ultrahigh-performance liquid chromatography has been used for the separation and analysis of unmodified and modified antisense oligonucleotides. For this reason, we tested various columns of low particle sizes in our analysis of unmodified and phosphorothioate oligonucleotides. The influence of both...

Descripción completa

Detalles Bibliográficos
Autores principales: Studzińska, Sylwia, Buszewski, Bogusław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206774/
https://www.ncbi.nlm.nih.gov/pubmed/24939137
http://dx.doi.org/10.1007/s00216-014-7959-5
_version_ 1782340868252893184
author Studzińska, Sylwia
Buszewski, Bogusław
author_facet Studzińska, Sylwia
Buszewski, Bogusław
author_sort Studzińska, Sylwia
collection PubMed
description Ultrahigh-performance liquid chromatography has been used for the separation and analysis of unmodified and modified antisense oligonucleotides. For this reason, we tested various columns of low particle sizes in our analysis of unmodified and phosphorothioate oligonucleotides. The influence of both the type and concentration of ion-pair reagent on the retention of the studied biomolecules was tested. The developed methods were used for separation of unmodified oligonucleotides and to determine antisense oligonucleotides in human serum samples. The results proved that octadecyl and phenyl columns are the most selective in the resolution of oligonucleotides which differ in the position of single nucleotides in the sequence. The phenyl column was selected and applied for the analysis of phosphorothioate oligonucleotides in serum samples. The calibration plots showed good linearity within the test concentration ranges. The intra-day CV of the calibration curve slopes was in the range of 1.6 to 4.2 %. The limits of detection (LODs) were in the range of 0.11–0.16 μg mL(−1), while the limit of quantification (LOQ) values were between 0.35 and 0.51 μg mL(−1). [Figure: see text]
format Online
Article
Text
id pubmed-4206774
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-42067742014-10-28 Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides Studzińska, Sylwia Buszewski, Bogusław Anal Bioanal Chem Research Paper Ultrahigh-performance liquid chromatography has been used for the separation and analysis of unmodified and modified antisense oligonucleotides. For this reason, we tested various columns of low particle sizes in our analysis of unmodified and phosphorothioate oligonucleotides. The influence of both the type and concentration of ion-pair reagent on the retention of the studied biomolecules was tested. The developed methods were used for separation of unmodified oligonucleotides and to determine antisense oligonucleotides in human serum samples. The results proved that octadecyl and phenyl columns are the most selective in the resolution of oligonucleotides which differ in the position of single nucleotides in the sequence. The phenyl column was selected and applied for the analysis of phosphorothioate oligonucleotides in serum samples. The calibration plots showed good linearity within the test concentration ranges. The intra-day CV of the calibration curve slopes was in the range of 1.6 to 4.2 %. The limits of detection (LODs) were in the range of 0.11–0.16 μg mL(−1), while the limit of quantification (LOQ) values were between 0.35 and 0.51 μg mL(−1). [Figure: see text] Springer Berlin Heidelberg 2014-06-18 2014 /pmc/articles/PMC4206774/ /pubmed/24939137 http://dx.doi.org/10.1007/s00216-014-7959-5 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Paper
Studzińska, Sylwia
Buszewski, Bogusław
Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title_full Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title_fullStr Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title_full_unstemmed Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title_short Evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
title_sort evaluation of ultrahigh-performance liquid chromatography columns for the analysis of unmodified and antisense oligonucleotides
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206774/
https://www.ncbi.nlm.nih.gov/pubmed/24939137
http://dx.doi.org/10.1007/s00216-014-7959-5
work_keys_str_mv AT studzinskasylwia evaluationofultrahighperformanceliquidchromatographycolumnsfortheanalysisofunmodifiedandantisenseoligonucleotides
AT buszewskibogusław evaluationofultrahighperformanceliquidchromatographycolumnsfortheanalysisofunmodifiedandantisenseoligonucleotides