Cargando…

Comparison of resorbable plates and titanium plates for fixation stability of combined mandibular symphysis and angle fractures

OBJECTIVES: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures. MATERIALS AND METHODS: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received titanium plates while the exp...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Ho-Yong, Jung, Chang-Hwa, Kim, Seong-Yong, Cho, Jin-Yong, Ryu, Jae-Young, Kim, Hyeon-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Association of Oral and Maxillofacial Surgeons 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4279974/
https://www.ncbi.nlm.nih.gov/pubmed/25551093
http://dx.doi.org/10.5125/jkaoms.2014.40.6.285