HISTOMORPHOMETRIC ANALYSIS OF PURE TITANIUM IMPLANTS WITH POROUS SURFACE VERSUS ROUGH SURFACE
The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in...