Cargando…
Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma
A selective and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) has been developed and validated for the quantification of zileuton in human plasma. Deuterated internal standard (zileuton D4) was used as the internal standard (ISTD). Zileuton was extracted by liquid-liqui...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientia Pharmaceutica
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4339974/ https://www.ncbi.nlm.nih.gov/pubmed/25853069 http://dx.doi.org/10.3797/scipharm.1402-19 |
_version_ | 1782358953163751424 |
---|---|
author | Prakash, Katakam Adiki, Shanta K Kalakuntla, Rama Rao |
author_facet | Prakash, Katakam Adiki, Shanta K Kalakuntla, Rama Rao |
author_sort | Prakash, Katakam |
collection | PubMed |
description | A selective and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) has been developed and validated for the quantification of zileuton in human plasma. Deuterated internal standard (zileuton D4) was used as the internal standard (ISTD). Zileuton was extracted by liquid-liquid extraction using methyl tert-butyl ether and separated by isocratic elution on a C18 column (100 × 4.6 mm, 5 μm, Discovery C18) with the mobile phase consisting of 1 mM ammonium acetate buffer and methanol in the ratio of 10:90. A flow rate of 1.0 ml/min was used with isocratic elution. Multiple reaction monitoring transitions in positive mode for zileuton and the internal standard were 237.3/161.2 and 241.2/161.1, respectively. The method was validated within the linearity range of 50.5–10,012.7 ng/ml for the bioanalytical method validation parameters like selectivity, accuracy, precision, recovery, stability, and matrix effect. |
format | Online Article Text |
id | pubmed-4339974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Scientia Pharmaceutica |
record_format | MEDLINE/PubMed |
spelling | pubmed-43399742015-04-07 Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma Prakash, Katakam Adiki, Shanta K Kalakuntla, Rama Rao Sci Pharm Research Article A selective and sensitive liquid chromatography-tandem mass spectrometric method (LC-MS/MS) has been developed and validated for the quantification of zileuton in human plasma. Deuterated internal standard (zileuton D4) was used as the internal standard (ISTD). Zileuton was extracted by liquid-liquid extraction using methyl tert-butyl ether and separated by isocratic elution on a C18 column (100 × 4.6 mm, 5 μm, Discovery C18) with the mobile phase consisting of 1 mM ammonium acetate buffer and methanol in the ratio of 10:90. A flow rate of 1.0 ml/min was used with isocratic elution. Multiple reaction monitoring transitions in positive mode for zileuton and the internal standard were 237.3/161.2 and 241.2/161.1, respectively. The method was validated within the linearity range of 50.5–10,012.7 ng/ml for the bioanalytical method validation parameters like selectivity, accuracy, precision, recovery, stability, and matrix effect. Scientia Pharmaceutica 2014-03-26 2014 /pmc/articles/PMC4339974/ /pubmed/25853069 http://dx.doi.org/10.3797/scipharm.1402-19 Text en © Prakash et al.; licensee Österreichische Apotheker-Verlagsgesellschaft m. b. H., Vienna, Austria. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Prakash, Katakam Adiki, Shanta K Kalakuntla, Rama Rao Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title | Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title_full | Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title_fullStr | Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title_full_unstemmed | Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title_short | Development and Validation of a Liquid Chromatography-Mass Spectrometry Method for the Determination of Zileuton in Human Plasma |
title_sort | development and validation of a liquid chromatography-mass spectrometry method for the determination of zileuton in human plasma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4339974/ https://www.ncbi.nlm.nih.gov/pubmed/25853069 http://dx.doi.org/10.3797/scipharm.1402-19 |
work_keys_str_mv | AT prakashkatakam developmentandvalidationofaliquidchromatographymassspectrometrymethodforthedeterminationofzileutoninhumanplasma AT adikishantak developmentandvalidationofaliquidchromatographymassspectrometrymethodforthedeterminationofzileutoninhumanplasma AT kalakuntlaramarao developmentandvalidationofaliquidchromatographymassspectrometrymethodforthedeterminationofzileutoninhumanplasma |