Cargando…

Comparison of three different techniques of low-dose-rate seed implantation for prostate cancer

PURPOSE: Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS: The data of 305 prostate cancer patients who...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishiyama, Hiromichi, Satoh, Takefumi, Sekiguchi, Akane, Tabata, Ken-ichi, Komori, Shouko, Tsumura, Hideyasu, Kawakami, Shogo, Soda, Itaru, Takenaka, Kouji, Iwamura, Masatsugu, Hayakawa, Kazushige
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4371061/
https://www.ncbi.nlm.nih.gov/pubmed/25829930
http://dx.doi.org/10.5114/jcb.2015.48603