Cargando…

Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC

We describe an analytical methodology to obtain high sensitivity and better resolution through the study of fluorometric excitation (λ (ex)) and emission (λ (em)) spectrum wavelengths of OPA–amino acids. The spectrum emission study revealed a maximum signal peak at 450 nm for aspartate and glutamine...

Descripción completa

Detalles Bibliográficos
Autores principales: Perucho, J., Gonzalo-Gobernado, R., Bazan, E., Casarejos, M. J., Jiménez-Escrig, A., Asensio, M. J., Herranz, A. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4412611/
https://www.ncbi.nlm.nih.gov/pubmed/25691143
http://dx.doi.org/10.1007/s00726-015-1925-1
_version_ 1782368690188058624
author Perucho, J.
Gonzalo-Gobernado, R.
Bazan, E.
Casarejos, M. J.
Jiménez-Escrig, A.
Asensio, M. J.
Herranz, A. S.
author_facet Perucho, J.
Gonzalo-Gobernado, R.
Bazan, E.
Casarejos, M. J.
Jiménez-Escrig, A.
Asensio, M. J.
Herranz, A. S.
author_sort Perucho, J.
collection PubMed
description We describe an analytical methodology to obtain high sensitivity and better resolution through the study of fluorometric excitation (λ (ex)) and emission (λ (em)) spectrum wavelengths of OPA–amino acids. The spectrum emission study revealed a maximum signal peak at 450 nm for aspartate and glutamine. For glycine, taurine, and GABA, the maximum signal peak was at 448 and for glutamate at 452 nm. The remaining amino acids analyzed showed a maximum emission around 450 nm. The best signal obtained within the spectrum excitation experiments was using 229- to 450-nm λ (ex)–λ (em). The drawbacks observed at these wavelengths were a baseline drift and negative peaks occurrence. Thus, the excitation wavelength of 240 nm was chosen (240- to 450-nm λ (ex)–λ (em)) as a compromise between a very good signal response and a baseline stability to resolve the 18 amino acids studied. Furthermore, this protocol was properly validated. On the other hand, the elution gradient program used for neuroactive amino acids (aspartate, glutamate, glycine, taurine and GABA) showed separation to the baseline, in a 15-min run in all of them. Other amino acids, up to 18, also exhibited a very good separation in a 25-min run. In conclusion, we propose the use of 240- to 450-nm λ (ex)–λ (em) wavelengths, in OPA–amino acids analysis, as the most suitable protocol to obtain the best signal response, maintaining an optimum chromatographic resolution. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00726-015-1925-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4412611
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-44126112015-05-06 Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC Perucho, J. Gonzalo-Gobernado, R. Bazan, E. Casarejos, M. J. Jiménez-Escrig, A. Asensio, M. J. Herranz, A. S. Amino Acids Original Article We describe an analytical methodology to obtain high sensitivity and better resolution through the study of fluorometric excitation (λ (ex)) and emission (λ (em)) spectrum wavelengths of OPA–amino acids. The spectrum emission study revealed a maximum signal peak at 450 nm for aspartate and glutamine. For glycine, taurine, and GABA, the maximum signal peak was at 448 and for glutamate at 452 nm. The remaining amino acids analyzed showed a maximum emission around 450 nm. The best signal obtained within the spectrum excitation experiments was using 229- to 450-nm λ (ex)–λ (em). The drawbacks observed at these wavelengths were a baseline drift and negative peaks occurrence. Thus, the excitation wavelength of 240 nm was chosen (240- to 450-nm λ (ex)–λ (em)) as a compromise between a very good signal response and a baseline stability to resolve the 18 amino acids studied. Furthermore, this protocol was properly validated. On the other hand, the elution gradient program used for neuroactive amino acids (aspartate, glutamate, glycine, taurine and GABA) showed separation to the baseline, in a 15-min run in all of them. Other amino acids, up to 18, also exhibited a very good separation in a 25-min run. In conclusion, we propose the use of 240- to 450-nm λ (ex)–λ (em) wavelengths, in OPA–amino acids analysis, as the most suitable protocol to obtain the best signal response, maintaining an optimum chromatographic resolution. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00726-015-1925-1) contains supplementary material, which is available to authorized users. Springer Vienna 2015-02-18 2015 /pmc/articles/PMC4412611/ /pubmed/25691143 http://dx.doi.org/10.1007/s00726-015-1925-1 Text en © The Author(s) 2015 https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Perucho, J.
Gonzalo-Gobernado, R.
Bazan, E.
Casarejos, M. J.
Jiménez-Escrig, A.
Asensio, M. J.
Herranz, A. S.
Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title_full Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title_fullStr Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title_full_unstemmed Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title_short Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC
title_sort optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn opa-derivatization by hplc
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4412611/
https://www.ncbi.nlm.nih.gov/pubmed/25691143
http://dx.doi.org/10.1007/s00726-015-1925-1
work_keys_str_mv AT peruchoj optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT gonzalogobernador optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT bazane optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT casarejosmj optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT jimenezescriga optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT asensiomj optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc
AT herranzas optimalexcitationandemissionwavelengthstoanalyzeaminoacidsandoptimizeneurotransmittersquantificationusingprecolumnopaderivatizationbyhplc