Cargando…

Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task

Focused Ultrasound (FUS) coupled with intravenous administration of microbubbles (MB) is a non-invasive technique that has been shown to reliably open (increase the permeability of) the blood-brain barrier (BBB) in multiple in vivo models including non-human primates (NHP). This procedure has shown...

Descripción completa

Detalles Bibliográficos
Autores principales: Downs, Matthew E., Buch, Amanda, Sierra, Carlos, Karakatsani, Maria Eleni, Chen, Shangshang, Konofagou, Elisa E., Ferrera, Vincent P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422704/
https://www.ncbi.nlm.nih.gov/pubmed/25945493
http://dx.doi.org/10.1371/journal.pone.0125911
_version_ 1782370098753830912
author Downs, Matthew E.
Buch, Amanda
Sierra, Carlos
Karakatsani, Maria Eleni
Chen, Shangshang
Konofagou, Elisa E.
Ferrera, Vincent P.
author_facet Downs, Matthew E.
Buch, Amanda
Sierra, Carlos
Karakatsani, Maria Eleni
Chen, Shangshang
Konofagou, Elisa E.
Ferrera, Vincent P.
author_sort Downs, Matthew E.
collection PubMed
description Focused Ultrasound (FUS) coupled with intravenous administration of microbubbles (MB) is a non-invasive technique that has been shown to reliably open (increase the permeability of) the blood-brain barrier (BBB) in multiple in vivo models including non-human primates (NHP). This procedure has shown promise for clinical and basic science applications, yet the safety and potential neurological effects of long term application in NHP requires further investigation under parameters shown to be efficacious in that species (500kHz, 200–400 kPa, 4–5μm MB, 2 minute sonication). In this study, we repeatedly opened the BBB in the caudate and putamen regions of the basal ganglia of 4 NHP using FUS with systemically-administered MB over 4–20 months. We assessed the safety of the FUS with MB procedure using MRI to detect edema or hemorrhaging in the brain. Contrast enhanced T1-weighted MRI sequences showed a 98% success rate for openings in the targeted regions. T2-weighted and SWI sequences indicated a lack edema in the majority of the cases. We investigated potential neurological effects of the FUS with MB procedure through quantitative cognitive testing of’ visual, cognitive, motivational, and motor function using a random dot motion task with reward magnitude bias presented on a touchpanel display. Reaction times during the task significantly increased on the day of the FUS with MB procedure. This increase returned to baseline within 4–5 days after the procedure. Visual motion discrimination thresholds were unaffected. Our results indicate FUS with MB can be a safe method for repeated opening of the BBB at the basal ganglia in NHP for up to 20 months without any long-term negative physiological or neurological effects with the parameters used.
format Online
Article
Text
id pubmed-4422704
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44227042015-05-12 Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task Downs, Matthew E. Buch, Amanda Sierra, Carlos Karakatsani, Maria Eleni Chen, Shangshang Konofagou, Elisa E. Ferrera, Vincent P. PLoS One Research Article Focused Ultrasound (FUS) coupled with intravenous administration of microbubbles (MB) is a non-invasive technique that has been shown to reliably open (increase the permeability of) the blood-brain barrier (BBB) in multiple in vivo models including non-human primates (NHP). This procedure has shown promise for clinical and basic science applications, yet the safety and potential neurological effects of long term application in NHP requires further investigation under parameters shown to be efficacious in that species (500kHz, 200–400 kPa, 4–5μm MB, 2 minute sonication). In this study, we repeatedly opened the BBB in the caudate and putamen regions of the basal ganglia of 4 NHP using FUS with systemically-administered MB over 4–20 months. We assessed the safety of the FUS with MB procedure using MRI to detect edema or hemorrhaging in the brain. Contrast enhanced T1-weighted MRI sequences showed a 98% success rate for openings in the targeted regions. T2-weighted and SWI sequences indicated a lack edema in the majority of the cases. We investigated potential neurological effects of the FUS with MB procedure through quantitative cognitive testing of’ visual, cognitive, motivational, and motor function using a random dot motion task with reward magnitude bias presented on a touchpanel display. Reaction times during the task significantly increased on the day of the FUS with MB procedure. This increase returned to baseline within 4–5 days after the procedure. Visual motion discrimination thresholds were unaffected. Our results indicate FUS with MB can be a safe method for repeated opening of the BBB at the basal ganglia in NHP for up to 20 months without any long-term negative physiological or neurological effects with the parameters used. Public Library of Science 2015-05-06 /pmc/articles/PMC4422704/ /pubmed/25945493 http://dx.doi.org/10.1371/journal.pone.0125911 Text en © 2015 Downs et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Downs, Matthew E.
Buch, Amanda
Sierra, Carlos
Karakatsani, Maria Eleni
Chen, Shangshang
Konofagou, Elisa E.
Ferrera, Vincent P.
Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title_full Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title_fullStr Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title_full_unstemmed Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title_short Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task
title_sort long-term safety of repeated blood-brain barrier opening via focused ultrasound with microbubbles in non-human primates performing a cognitive task
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422704/
https://www.ncbi.nlm.nih.gov/pubmed/25945493
http://dx.doi.org/10.1371/journal.pone.0125911
work_keys_str_mv AT downsmatthewe longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT buchamanda longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT sierracarlos longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT karakatsanimariaeleni longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT chenshangshang longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT konofagouelisae longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask
AT ferreravincentp longtermsafetyofrepeatedbloodbrainbarrieropeningviafocusedultrasoundwithmicrobubblesinnonhumanprimatesperformingacognitivetask