Cargando…
Stability-Indicating High-Performance Liquid Chromatographic Determination of Apixaban in the Presence of Degradation Products
A simple, robust, and stability-indicating reversed-phase high-performance liquid chromatographic (HPLC) method for the analysis of apixaban and its related substances has been successfully developed. Chromatography was performed on a 250 mm × 4.6 mm, 5 μm C(18) column with a gradient mixture of a p...
Autores principales: | Prabhune, Swarup Suresh, Jaguste, Rajendra Shankar, Kondalkar, Prakash Laxman, Pradhan, Nitin Sharadchandra |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientia Pharmaceutica
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4475800/ https://www.ncbi.nlm.nih.gov/pubmed/26171323 http://dx.doi.org/10.3797/scipharm.1403-25 |
Ejemplares similares
-
Rapid Liquid Chromatographic Method for the Determination of Roflumilast in the Presence of Degradation Products
por: Barhate, V D, et al.
Publicado: (2010) -
A Validated Stability-Indicating Liquid Chromatographic Method for Determination of Degradation Impurities and Diastereomers in Voriconazole Tablets
por: Shaikh, Kabeer A., et al.
Publicado: (2012) -
Stability-indicating liquid chromatographic method for the determination of Letrozole in pharmaceutical formulations
por: Annapurna, M. Mathrusri, et al.
Publicado: (2012) -
A developed and validated stability-indicating reverse-phase high performance liquid chromatographic method for determination of cefdinir in the presence of its degradation products as per International Conference on Harmonization guidelines
por: Hamrapurkar, Purnima, et al.
Publicado: (2011) -
A Validated Stability-Indicating Liquid-Chromatographic Method for Ranitidine Hydrochloride in Liquid Oral Dosage Form
por: Sharma, Nitish, et al.
Publicado: (2011)