Cargando…

Realistic wave-optics simulation of X-ray phase-contrast imaging at a human scale

X-ray phase-contrast imaging (XPCI) can dramatically improve soft tissue contrast in X-ray medical imaging. Despite worldwide efforts to develop novel XPCI systems, a numerical framework to rigorously predict the performance of a clinical XPCI system at a human scale is not yet available. We have de...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Yongjin, Segars, W. Paul, Pan, Adam, Ando, Masami, Sheppard, Colin J. R., Gupta, Rajiv
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4500945/
https://www.ncbi.nlm.nih.gov/pubmed/26169570
http://dx.doi.org/10.1038/srep12011