Cargando…

A Rare Case of a Lost Suture Needle during Third Molar Surgery

The authors report a case that is started with a simple upper third molar's surgical extraction and a broken 3.0 suture needle tip incident occurred. Broken fragment's localization has been detected with 3D cone beam computed tomography (CBCT). Needle tip has been reached with the help of...

Descripción completa

Detalles Bibliográficos
Autores principales: Aktop, Sertac, Gocmen, Gokhan, Özturk, M. Elif, Gonul, Onur, Varol, Altan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4549529/
https://www.ncbi.nlm.nih.gov/pubmed/26347829
http://dx.doi.org/10.1155/2015/372153