Cargando…

Accounting for partiality in serial crystallography using ray-tracing principles

Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction...

Descripción completa

Detalles Bibliográficos
Autores principales: Kroon-Batenburg, Loes M. J., Schreurs, Antoine M. M., Ravelli, Raimond B. G., Gros, Piet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4556312/
https://www.ncbi.nlm.nih.gov/pubmed/26327370
http://dx.doi.org/10.1107/S1399004715011803
_version_ 1782388332641124352
author Kroon-Batenburg, Loes M. J.
Schreurs, Antoine M. M.
Ravelli, Raimond B. G.
Gros, Piet
author_facet Kroon-Batenburg, Loes M. J.
Schreurs, Antoine M. M.
Ravelli, Raimond B. G.
Gros, Piet
author_sort Kroon-Batenburg, Loes M. J.
collection PubMed
description Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R (int) factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R (int) of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography.
format Online
Article
Text
id pubmed-4556312
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-45563122015-09-22 Accounting for partiality in serial crystallography using ray-tracing principles Kroon-Batenburg, Loes M. J. Schreurs, Antoine M. M. Ravelli, Raimond B. G. Gros, Piet Acta Crystallogr D Biol Crystallogr Research Papers Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R (int) factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R (int) of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography. International Union of Crystallography 2015-08-25 /pmc/articles/PMC4556312/ /pubmed/26327370 http://dx.doi.org/10.1107/S1399004715011803 Text en © Kroon-Batenburg et al. 2015 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Kroon-Batenburg, Loes M. J.
Schreurs, Antoine M. M.
Ravelli, Raimond B. G.
Gros, Piet
Accounting for partiality in serial crystallography using ray-tracing principles
title Accounting for partiality in serial crystallography using ray-tracing principles
title_full Accounting for partiality in serial crystallography using ray-tracing principles
title_fullStr Accounting for partiality in serial crystallography using ray-tracing principles
title_full_unstemmed Accounting for partiality in serial crystallography using ray-tracing principles
title_short Accounting for partiality in serial crystallography using ray-tracing principles
title_sort accounting for partiality in serial crystallography using ray-tracing principles
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4556312/
https://www.ncbi.nlm.nih.gov/pubmed/26327370
http://dx.doi.org/10.1107/S1399004715011803
work_keys_str_mv AT kroonbatenburgloesmj accountingforpartialityinserialcrystallographyusingraytracingprinciples
AT schreursantoinemm accountingforpartialityinserialcrystallographyusingraytracingprinciples
AT ravelliraimondbg accountingforpartialityinserialcrystallographyusingraytracingprinciples
AT grospiet accountingforpartialityinserialcrystallographyusingraytracingprinciples