Noninvasive calculation of the aortic blood pressure waveform from the flow velocity waveform: a proof of concept

Estimation of aortic and left ventricular (LV) pressure usually requires measurements that are difficult to acquire during the imaging required to obtain concurrent LV dimensions essential for determination of LV mechanical properties. We describe a novel method for deriving aortic pressure from the...

Descripción completa

Detalles Bibliográficos
Autores principales: Vennin, Samuel, Mayer, Alexia, Li, Ye, Fok, Henry, Clapp, Brian, Alastruey, Jordi, Chowienczyk, Phil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Physiological Society 2015