Cargando…
Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations
Purpose. The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. Materials and Methods. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restora...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628743/ https://www.ncbi.nlm.nih.gov/pubmed/26557681 http://dx.doi.org/10.1155/2015/619027 |