Cargando…

Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy

In this paper, the performance of two Kalman filter (KF) schemes based on the direct estimated model and differencing estimated model for input rate signal was thoroughly analyzed and compared for combining measurements of a sensor array to improve the accuracy of microelectromechanical system (MEMS...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Guangmin, Yuan, Weizheng, Xue, Liang, Xie, Jianbing, Chang, Honglong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701246/
https://www.ncbi.nlm.nih.gov/pubmed/26528980
http://dx.doi.org/10.3390/s151127590
_version_ 1782408443141816320
author Yuan, Guangmin
Yuan, Weizheng
Xue, Liang
Xie, Jianbing
Chang, Honglong
author_facet Yuan, Guangmin
Yuan, Weizheng
Xue, Liang
Xie, Jianbing
Chang, Honglong
author_sort Yuan, Guangmin
collection PubMed
description In this paper, the performance of two Kalman filter (KF) schemes based on the direct estimated model and differencing estimated model for input rate signal was thoroughly analyzed and compared for combining measurements of a sensor array to improve the accuracy of microelectromechanical system (MEMS) gyroscopes. The principles for noise reduction were presented and KF algorithms were designed to obtain the optimal rate signal estimates. The input rate signal in the direct estimated KF model was modeled with a random walk process and treated as the estimated system state. In the differencing estimated KF model, a differencing operation was established between outputs of the gyroscope array, and then the optimal estimation of input rate signal was achieved by compensating for the estimations of bias drifts for the component gyroscopes. Finally, dynamic simulations and experiments with a six-gyroscope array were implemented to compare the dynamic performance of the two KF models. The 1σ error of the gyroscopes was reduced from 1.4558°/s to 0.1203°/s by the direct estimated KF model in a constant rate test and to 0.5974°/s by the differencing estimated KF model. The estimated rate signal filtered by both models could reflect the amplitude variation of the input signal in the swing rate test and displayed a reduction factor of about three for the 1σ noise. Results illustrate that the performance of the direct estimated KF model is much higher than that of the differencing estimated KF model, with a constant input signal or lower dynamic variation. A similarity in the two KFs’ performance is observed if the input signal has a high dynamic variation.
format Online
Article
Text
id pubmed-4701246
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-47012462016-01-19 Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy Yuan, Guangmin Yuan, Weizheng Xue, Liang Xie, Jianbing Chang, Honglong Sensors (Basel) Article In this paper, the performance of two Kalman filter (KF) schemes based on the direct estimated model and differencing estimated model for input rate signal was thoroughly analyzed and compared for combining measurements of a sensor array to improve the accuracy of microelectromechanical system (MEMS) gyroscopes. The principles for noise reduction were presented and KF algorithms were designed to obtain the optimal rate signal estimates. The input rate signal in the direct estimated KF model was modeled with a random walk process and treated as the estimated system state. In the differencing estimated KF model, a differencing operation was established between outputs of the gyroscope array, and then the optimal estimation of input rate signal was achieved by compensating for the estimations of bias drifts for the component gyroscopes. Finally, dynamic simulations and experiments with a six-gyroscope array were implemented to compare the dynamic performance of the two KF models. The 1σ error of the gyroscopes was reduced from 1.4558°/s to 0.1203°/s by the direct estimated KF model in a constant rate test and to 0.5974°/s by the differencing estimated KF model. The estimated rate signal filtered by both models could reflect the amplitude variation of the input signal in the swing rate test and displayed a reduction factor of about three for the 1σ noise. Results illustrate that the performance of the direct estimated KF model is much higher than that of the differencing estimated KF model, with a constant input signal or lower dynamic variation. A similarity in the two KFs’ performance is observed if the input signal has a high dynamic variation. MDPI 2015-10-30 /pmc/articles/PMC4701246/ /pubmed/26528980 http://dx.doi.org/10.3390/s151127590 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yuan, Guangmin
Yuan, Weizheng
Xue, Liang
Xie, Jianbing
Chang, Honglong
Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title_full Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title_fullStr Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title_full_unstemmed Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title_short Dynamic Performance Comparison of Two Kalman Filters for Rate Signal Direct Modeling and Differencing Modeling for Combining a MEMS Gyroscope Array to Improve Accuracy
title_sort dynamic performance comparison of two kalman filters for rate signal direct modeling and differencing modeling for combining a mems gyroscope array to improve accuracy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701246/
https://www.ncbi.nlm.nih.gov/pubmed/26528980
http://dx.doi.org/10.3390/s151127590
work_keys_str_mv AT yuanguangmin dynamicperformancecomparisonoftwokalmanfiltersforratesignaldirectmodelinganddifferencingmodelingforcombiningamemsgyroscopearraytoimproveaccuracy
AT yuanweizheng dynamicperformancecomparisonoftwokalmanfiltersforratesignaldirectmodelinganddifferencingmodelingforcombiningamemsgyroscopearraytoimproveaccuracy
AT xueliang dynamicperformancecomparisonoftwokalmanfiltersforratesignaldirectmodelinganddifferencingmodelingforcombiningamemsgyroscopearraytoimproveaccuracy
AT xiejianbing dynamicperformancecomparisonoftwokalmanfiltersforratesignaldirectmodelinganddifferencingmodelingforcombiningamemsgyroscopearraytoimproveaccuracy
AT changhonglong dynamicperformancecomparisonoftwokalmanfiltersforratesignaldirectmodelinganddifferencingmodelingforcombiningamemsgyroscopearraytoimproveaccuracy