Cargando…

Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics

Efficient and robust separation methods are indispensable in modern LC-MS based metabolomics, where high-resolution mass spectrometers are challenged by isomeric and isobaric metabolites. The optimization of chromatographic separation hence remains an invaluable tool in the comprehensive analysis of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ortmayr, Karin, Hann, Stephan, Koellensperger, Gunda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Royal Society of Chemistry 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719141/
https://www.ncbi.nlm.nih.gov/pubmed/25824707
http://dx.doi.org/10.1039/c5an00206k
_version_ 1782410886549340160
author Ortmayr, Karin
Hann, Stephan
Koellensperger, Gunda
author_facet Ortmayr, Karin
Hann, Stephan
Koellensperger, Gunda
author_sort Ortmayr, Karin
collection PubMed
description Efficient and robust separation methods are indispensable in modern LC-MS based metabolomics, where high-resolution mass spectrometers are challenged by isomeric and isobaric metabolites. The optimization of chromatographic separation hence remains an invaluable tool in the comprehensive analysis of the chemically diverse intracellular metabolome. While it is widely accepted that a single method with comprehensive metabolome coverage does not exist, the potential of combining different chromatographic selectivities in two-dimensional liquid chromatography is underestimated in the field. Here, we introduce a novel separation system combining reversed-phase and porous graphitized carbon liquid chromatography in a heart-cut on-line two-dimensional setup for mass spectrometry. The proposed experimental setup can be readily implemented using standard HPLC equipment with only one additional HPLC pump and a two-position six-port valve. The method proved to be robust with excellent retention time stability (average 0.4%) even in the presence of biological matrix. Testing the presented approach on a test mixture of 82 relevant intracellular metabolites, the number of metabolites that are retained could be doubled as compared to reversed-phase liquid chromatography alone. The presented work further demonstrates how the distinct selectivity of porous graphitized carbon complements reversed-phase liquid chromatography and extends the metabolome coverage of conventional LC-MS based methods in metabolomics to biologically important, but analytically challenging compound groups such as sugar phosphates. Both metabolic profiling and metabolic fingerprinting benefit from this method's increased separation capabilities that enhance sample throughput and the biological information content of LC-MS data. An inter-platform comparison with GC- and LC-tandem MS analyses confirmed the validity of the presented two-dimensional approach in the analysis of yeast cell extracts from P. pastoris.
format Online
Article
Text
id pubmed-4719141
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-47191412016-02-01 Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics Ortmayr, Karin Hann, Stephan Koellensperger, Gunda Analyst Chemistry Efficient and robust separation methods are indispensable in modern LC-MS based metabolomics, where high-resolution mass spectrometers are challenged by isomeric and isobaric metabolites. The optimization of chromatographic separation hence remains an invaluable tool in the comprehensive analysis of the chemically diverse intracellular metabolome. While it is widely accepted that a single method with comprehensive metabolome coverage does not exist, the potential of combining different chromatographic selectivities in two-dimensional liquid chromatography is underestimated in the field. Here, we introduce a novel separation system combining reversed-phase and porous graphitized carbon liquid chromatography in a heart-cut on-line two-dimensional setup for mass spectrometry. The proposed experimental setup can be readily implemented using standard HPLC equipment with only one additional HPLC pump and a two-position six-port valve. The method proved to be robust with excellent retention time stability (average 0.4%) even in the presence of biological matrix. Testing the presented approach on a test mixture of 82 relevant intracellular metabolites, the number of metabolites that are retained could be doubled as compared to reversed-phase liquid chromatography alone. The presented work further demonstrates how the distinct selectivity of porous graphitized carbon complements reversed-phase liquid chromatography and extends the metabolome coverage of conventional LC-MS based methods in metabolomics to biologically important, but analytically challenging compound groups such as sugar phosphates. Both metabolic profiling and metabolic fingerprinting benefit from this method's increased separation capabilities that enhance sample throughput and the biological information content of LC-MS data. An inter-platform comparison with GC- and LC-tandem MS analyses confirmed the validity of the presented two-dimensional approach in the analysis of yeast cell extracts from P. pastoris. Royal Society of Chemistry 2015-05-05 2015-05-21 /pmc/articles/PMC4719141/ /pubmed/25824707 http://dx.doi.org/10.1039/c5an00206k Text en This journal is © The Royal Society of Chemistry 2015 http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution 3.0 Unported License (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Chemistry
Ortmayr, Karin
Hann, Stephan
Koellensperger, Gunda
Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title_full Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title_fullStr Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title_full_unstemmed Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title_short Complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional LC-MS setup for metabolomics
title_sort complementing reversed-phase selectivity with porous graphitized carbon to increase the metabolome coverage in an on-line two-dimensional lc-ms setup for metabolomics
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719141/
https://www.ncbi.nlm.nih.gov/pubmed/25824707
http://dx.doi.org/10.1039/c5an00206k
work_keys_str_mv AT ortmayrkarin complementingreversedphaseselectivitywithporousgraphitizedcarbontoincreasethemetabolomecoverageinanonlinetwodimensionallcmssetupformetabolomics
AT hannstephan complementingreversedphaseselectivitywithporousgraphitizedcarbontoincreasethemetabolomecoverageinanonlinetwodimensionallcmssetupformetabolomics
AT koellenspergergunda complementingreversedphaseselectivitywithporousgraphitizedcarbontoincreasethemetabolomecoverageinanonlinetwodimensionallcmssetupformetabolomics