Cargando…
Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for anal...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4757830/ https://www.ncbi.nlm.nih.gov/pubmed/26888486 http://dx.doi.org/10.1038/srep21433 |
_version_ | 1782416517984419840 |
---|---|
author | Liu, Ping Qi, Chu-Bo Zhu, Quan-Fei Yuan, Bi-Feng Feng, Yu-Qi |
author_facet | Liu, Ping Qi, Chu-Bo Zhu, Quan-Fei Yuan, Bi-Feng Feng, Yu-Qi |
author_sort | Liu, Ping |
collection | PubMed |
description | Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. |
format | Online Article Text |
id | pubmed-4757830 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-47578302016-02-25 Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis Liu, Ping Qi, Chu-Bo Zhu, Quan-Fei Yuan, Bi-Feng Feng, Yu-Qi Sci Rep Article Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. Nature Publishing Group 2016-02-18 /pmc/articles/PMC4757830/ /pubmed/26888486 http://dx.doi.org/10.1038/srep21433 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Liu, Ping Qi, Chu-Bo Zhu, Quan-Fei Yuan, Bi-Feng Feng, Yu-Qi Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title | Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title_full | Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title_fullStr | Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title_full_unstemmed | Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title_short | Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
title_sort | determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4757830/ https://www.ncbi.nlm.nih.gov/pubmed/26888486 http://dx.doi.org/10.1038/srep21433 |
work_keys_str_mv | AT liuping determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis AT qichubo determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis AT zhuquanfei determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis AT yuanbifeng determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis AT fengyuqi determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis |