Cargando…

Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis

Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for anal...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Ping, Qi, Chu-Bo, Zhu, Quan-Fei, Yuan, Bi-Feng, Feng, Yu-Qi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4757830/
https://www.ncbi.nlm.nih.gov/pubmed/26888486
http://dx.doi.org/10.1038/srep21433
_version_ 1782416517984419840
author Liu, Ping
Qi, Chu-Bo
Zhu, Quan-Fei
Yuan, Bi-Feng
Feng, Yu-Qi
author_facet Liu, Ping
Qi, Chu-Bo
Zhu, Quan-Fei
Yuan, Bi-Feng
Feng, Yu-Qi
author_sort Liu, Ping
collection PubMed
description Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines.
format Online
Article
Text
id pubmed-4757830
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-47578302016-02-25 Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis Liu, Ping Qi, Chu-Bo Zhu, Quan-Fei Yuan, Bi-Feng Feng, Yu-Qi Sci Rep Article Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for non-targeted profiling of thiols from cancer samples. Compared to traditional full scan mode, the DPI method significantly improved identification selectivity and accuracy. 103 thiol candidates were discovered in all cancers and 6 thiols were identified by their standards. It is worth noting that pantetheine, for the first time, was identified in human urine. Secondly, the IL-LC-MRM-MS method was developed for relative quantification of thiols in cancers compared to healthy controls. All the MRM transitions of light and heavy labeled thiols were acquired from urines by using DPI method. Compared to DPI method, the sensitivity of MRM improved by 2.1–11.3 folds. In addition, the concentration of homocysteine, γ-glutamylcysteine and pantetheine enhanced more than two folds in cancer patients compared to healthy controls. Taken together, the method demonstrated to be a promising strategy for identification and comprehensive quantification of thiols in human urines. Nature Publishing Group 2016-02-18 /pmc/articles/PMC4757830/ /pubmed/26888486 http://dx.doi.org/10.1038/srep21433 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Liu, Ping
Qi, Chu-Bo
Zhu, Quan-Fei
Yuan, Bi-Feng
Feng, Yu-Qi
Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title_full Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title_fullStr Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title_full_unstemmed Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title_short Determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
title_sort determination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4757830/
https://www.ncbi.nlm.nih.gov/pubmed/26888486
http://dx.doi.org/10.1038/srep21433
work_keys_str_mv AT liuping determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis
AT qichubo determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis
AT zhuquanfei determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis
AT yuanbifeng determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis
AT fengyuqi determinationofthiolmetabolitesinhumanurinebystableisotopelabelingincombinationwithpseudotargetedmassspectrometryanalysis