Cargando…

Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices

BACKGROUND: Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose con...

Descripción completa

Detalles Bibliográficos
Autores principales: Mair, B., Drillich, M., Klein-Jöbstl, D., Kanz, P., Borchardt, S., Meyer, L., Schwendenwein, I., Iwersen, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4765023/
https://www.ncbi.nlm.nih.gov/pubmed/26911673
http://dx.doi.org/10.1186/s12917-016-0662-3
_version_ 1782417484770443264
author Mair, B.
Drillich, M.
Klein-Jöbstl, D.
Kanz, P.
Borchardt, S.
Meyer, L.
Schwendenwein, I.
Iwersen, M.
author_facet Mair, B.
Drillich, M.
Klein-Jöbstl, D.
Kanz, P.
Borchardt, S.
Meyer, L.
Schwendenwein, I.
Iwersen, M.
author_sort Mair, B.
collection PubMed
description BACKGROUND: Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. RESULTS: The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73 % for the FSP, 81 % for the GLX and 41 % for the WGC. Bland-Altman plots showed biases of −18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80 %. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92 %, Sp = 85 %) and 95 mg/dL (Se = 39 %, Sp = 92 %). CONCLUSIONS: The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.
format Online
Article
Text
id pubmed-4765023
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47650232016-02-25 Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices Mair, B. Drillich, M. Klein-Jöbstl, D. Kanz, P. Borchardt, S. Meyer, L. Schwendenwein, I. Iwersen, M. BMC Vet Res Methodology Article BACKGROUND: Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. RESULTS: The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73 % for the FSP, 81 % for the GLX and 41 % for the WGC. Bland-Altman plots showed biases of −18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80 %. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92 %, Sp = 85 %) and 95 mg/dL (Se = 39 %, Sp = 92 %). CONCLUSIONS: The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations. BioMed Central 2016-02-24 /pmc/articles/PMC4765023/ /pubmed/26911673 http://dx.doi.org/10.1186/s12917-016-0662-3 Text en © Mair et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Methodology Article
Mair, B.
Drillich, M.
Klein-Jöbstl, D.
Kanz, P.
Borchardt, S.
Meyer, L.
Schwendenwein, I.
Iwersen, M.
Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title_full Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title_fullStr Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title_full_unstemmed Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title_short Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
title_sort glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4765023/
https://www.ncbi.nlm.nih.gov/pubmed/26911673
http://dx.doi.org/10.1186/s12917-016-0662-3
work_keys_str_mv AT mairb glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT drillichm glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT kleinjobstld glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT kanzp glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT borchardts glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT meyerl glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT schwendenweini glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices
AT iwersenm glucoseconcentrationincapillarybloodofdairycowsobtainedbyaminimallyinvasivelancettechniqueanddeterminedwiththreedifferenthandhelddevices