Cargando…
Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS:...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842859/ https://www.ncbi.nlm.nih.gov/pubmed/27134528 http://dx.doi.org/10.3348/kjr.2016.17.3.405 |
_version_ | 1782428596883685376 |
---|---|
author | Kim, Suyoung Shin, Joon-Ho Lee, Joon Woo Kang, Heung Sik Lee, Guen Young Ahn, Joong Mo |
author_facet | Kim, Suyoung Shin, Joon-Ho Lee, Joon Woo Kang, Heung Sik Lee, Guen Young Ahn, Joong Mo |
author_sort | Kim, Suyoung |
collection | PubMed |
description | OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. RESULTS: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. CONCLUSION: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM. |
format | Online Article Text |
id | pubmed-4842859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48428592016-05-01 Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients Kim, Suyoung Shin, Joon-Ho Lee, Joon Woo Kang, Heung Sik Lee, Guen Young Ahn, Joong Mo Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. RESULTS: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. CONCLUSION: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM. The Korean Society of Radiology 2016 2016-04-14 /pmc/articles/PMC4842859/ /pubmed/27134528 http://dx.doi.org/10.3348/kjr.2016.17.3.405 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Musculoskeletal Imaging Kim, Suyoung Shin, Joon-Ho Lee, Joon Woo Kang, Heung Sik Lee, Guen Young Ahn, Joong Mo Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title | Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title_full | Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title_fullStr | Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title_full_unstemmed | Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title_short | Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients |
title_sort | factors affecting radiation exposure during lumbar epidural steroid injection: a prospective study in 759 patients |
topic | Musculoskeletal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842859/ https://www.ncbi.nlm.nih.gov/pubmed/27134528 http://dx.doi.org/10.3348/kjr.2016.17.3.405 |
work_keys_str_mv | AT kimsuyoung factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients AT shinjoonho factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients AT leejoonwoo factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients AT kangheungsik factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients AT leeguenyoung factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients AT ahnjoongmo factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients |