Cargando…

Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients

OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Suyoung, Shin, Joon-Ho, Lee, Joon Woo, Kang, Heung Sik, Lee, Guen Young, Ahn, Joong Mo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842859/
https://www.ncbi.nlm.nih.gov/pubmed/27134528
http://dx.doi.org/10.3348/kjr.2016.17.3.405
_version_ 1782428596883685376
author Kim, Suyoung
Shin, Joon-Ho
Lee, Joon Woo
Kang, Heung Sik
Lee, Guen Young
Ahn, Joong Mo
author_facet Kim, Suyoung
Shin, Joon-Ho
Lee, Joon Woo
Kang, Heung Sik
Lee, Guen Young
Ahn, Joong Mo
author_sort Kim, Suyoung
collection PubMed
description OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. RESULTS: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. CONCLUSION: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM.
format Online
Article
Text
id pubmed-4842859
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-48428592016-05-01 Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients Kim, Suyoung Shin, Joon-Ho Lee, Joon Woo Kang, Heung Sik Lee, Guen Young Ahn, Joong Mo Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To estimate and compare radiation exposure and intervention time during lumbar epidural steroid injection (ESI) 1) under different practitioners and methods with continuous fluoroscopic monitoring, and 2) under one practitioner with different methods and monitoring. MATERIALS AND METHODS: We consecutively recruited 804 patients who underwent lumbar ESI and 759 patients who underwent 922 interventions were included for analysis in this investigation. Three different practitioners (a senior faculty member, junior faculty member, trainee) performed lumbar ESI using different methods (caudal, interlaminar, transforaminal). The senior faculty member performed lumbar ESI under two different methods of fluoroscopic monitoring (continuous [CM] and intermittent monitoring [IM]). The dose area product (DAP) fluoroscopy time, and intervention time during lumbar ESI were compared for 1) ESI methods and practitioners under CM, and 2) ESI methods and monitoring. RESULTS: With CM, interaction between the effects of the practitioner and the intervention on DAP was significant (p < 0.001), but not fluoroscopy time (p = 0.672) or intervention time (p = 0.852). The significant main effects included the practitioner and intervention on DAP, fluoroscopy time, and intervention time with CM (p < 0.001). DAPs and fluoroscopy time for caudal, interlaminar, and transforaminal ESI were higher with CM than with IM (p < 0.001). Intervention time did not differ between CM and IM. CONCLUSION: Radiation exposure is dependent on the practitioners and methods and within the established safety limits during lumbar ESIs under CM. With an experienced practitioner, IM leads to less radiation exposure than CM. The Korean Society of Radiology 2016 2016-04-14 /pmc/articles/PMC4842859/ /pubmed/27134528 http://dx.doi.org/10.3348/kjr.2016.17.3.405 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Kim, Suyoung
Shin, Joon-Ho
Lee, Joon Woo
Kang, Heung Sik
Lee, Guen Young
Ahn, Joong Mo
Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title_full Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title_fullStr Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title_full_unstemmed Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title_short Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients
title_sort factors affecting radiation exposure during lumbar epidural steroid injection: a prospective study in 759 patients
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842859/
https://www.ncbi.nlm.nih.gov/pubmed/27134528
http://dx.doi.org/10.3348/kjr.2016.17.3.405
work_keys_str_mv AT kimsuyoung factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients
AT shinjoonho factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients
AT leejoonwoo factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients
AT kangheungsik factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients
AT leeguenyoung factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients
AT ahnjoongmo factorsaffectingradiationexposureduringlumbarepiduralsteroidinjectionaprospectivestudyin759patients