Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy
For two-dimensional x-ray imaging of thin films, the technique of scanning transmission x-ray microscopy (STXM) has achieved images with feature sizes as small as 40 nm in recent years. However, calibration of three-dimensional tomographic images that are produced with STXM data at this scale has no...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
2000
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877146/ https://www.ncbi.nlm.nih.gov/pubmed/27551641 http://dx.doi.org/10.6028/jres.105.067 |
_version_ | 1782433339885486080 |
---|---|
author | Kalukin, Andrew R. Winn, Barry Wang, Yuxin Jacobsen, Chris Levine, Zachary H. Fu, Joseph |
author_facet | Kalukin, Andrew R. Winn, Barry Wang, Yuxin Jacobsen, Chris Levine, Zachary H. Fu, Joseph |
author_sort | Kalukin, Andrew R. |
collection | PubMed |
description | For two-dimensional x-ray imaging of thin films, the technique of scanning transmission x-ray microscopy (STXM) has achieved images with feature sizes as small as 40 nm in recent years. However, calibration of three-dimensional tomographic images that are produced with STXM data at this scale has not yet been described in the scientific literature, and the calibration procedure has novel problems that have not been encountered by x-ray tomography carried out at a larger scale. In x-ray microtomography, for example, one always has the option of using optical imaging on a section of the object to verify the x-ray projection measurements; with STXM, on the other hand, the sample features are too small to be resolved by light at optical wavelengths. This fact implies that one must rely on procedures with higher resolution, such as atomic force microscopy (AFM), for the calibration. Such procedures, however, generally depend on a highly destructive sectioning of the sample, and are difficult to interpret because they give surface information rather than depth information. In this article, a procedure for calibration is described that overcomes these limitations and achieves a calibration of an STXM tomography image with an AFM image and a scanning electron microscopy image of the same object. A Ge star-shaped pattern was imaged at a synchrotron with a scanning transmission x-ray microscope. Nineteen high-resolution projection images of 200 × 200 pixels were tomographically reconstructed into a three-dimensional image. Features in two-dimensional images as small as 40 nm and features as small as 80 nm in the three-dimensional reconstruction were resolved. Transverse length scales based on atomic force microscopy, scanning electron microscopy, x-ray transmission and tomographic reconstruction agreed to within 10 nm. Toward the center of the sample, the pattern thickness calculated from projection images was (51 ± 15) nm vs (80 ± 52) nm for tomographic reconstruction, where the uncertainties are evaluated at the level of two standard deviations. |
format | Online Article Text |
id | pubmed-4877146 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2000 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-48771462016-08-22 Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy Kalukin, Andrew R. Winn, Barry Wang, Yuxin Jacobsen, Chris Levine, Zachary H. Fu, Joseph J Res Natl Inst Stand Technol Article For two-dimensional x-ray imaging of thin films, the technique of scanning transmission x-ray microscopy (STXM) has achieved images with feature sizes as small as 40 nm in recent years. However, calibration of three-dimensional tomographic images that are produced with STXM data at this scale has not yet been described in the scientific literature, and the calibration procedure has novel problems that have not been encountered by x-ray tomography carried out at a larger scale. In x-ray microtomography, for example, one always has the option of using optical imaging on a section of the object to verify the x-ray projection measurements; with STXM, on the other hand, the sample features are too small to be resolved by light at optical wavelengths. This fact implies that one must rely on procedures with higher resolution, such as atomic force microscopy (AFM), for the calibration. Such procedures, however, generally depend on a highly destructive sectioning of the sample, and are difficult to interpret because they give surface information rather than depth information. In this article, a procedure for calibration is described that overcomes these limitations and achieves a calibration of an STXM tomography image with an AFM image and a scanning electron microscopy image of the same object. A Ge star-shaped pattern was imaged at a synchrotron with a scanning transmission x-ray microscope. Nineteen high-resolution projection images of 200 × 200 pixels were tomographically reconstructed into a three-dimensional image. Features in two-dimensional images as small as 40 nm and features as small as 80 nm in the three-dimensional reconstruction were resolved. Transverse length scales based on atomic force microscopy, scanning electron microscopy, x-ray transmission and tomographic reconstruction agreed to within 10 nm. Toward the center of the sample, the pattern thickness calculated from projection images was (51 ± 15) nm vs (80 ± 52) nm for tomographic reconstruction, where the uncertainties are evaluated at the level of two standard deviations. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2000 2000-12-01 /pmc/articles/PMC4877146/ /pubmed/27551641 http://dx.doi.org/10.6028/jres.105.067 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Kalukin, Andrew R. Winn, Barry Wang, Yuxin Jacobsen, Chris Levine, Zachary H. Fu, Joseph Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title | Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title_full | Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title_fullStr | Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title_full_unstemmed | Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title_short | Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy |
title_sort | calibration of high-resolution x-ray tomography with atomic force microscopy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4877146/ https://www.ncbi.nlm.nih.gov/pubmed/27551641 http://dx.doi.org/10.6028/jres.105.067 |
work_keys_str_mv | AT kalukinandrewr calibrationofhighresolutionxraytomographywithatomicforcemicroscopy AT winnbarry calibrationofhighresolutionxraytomographywithatomicforcemicroscopy AT wangyuxin calibrationofhighresolutionxraytomographywithatomicforcemicroscopy AT jacobsenchris calibrationofhighresolutionxraytomographywithatomicforcemicroscopy AT levinezacharyh calibrationofhighresolutionxraytomographywithatomicforcemicroscopy AT fujoseph calibrationofhighresolutionxraytomographywithatomicforcemicroscopy |