Cargando…

Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?

PURPOSE: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the prope...

Descripción completa

Detalles Bibliográficos
Autores principales: Eun, Na Lae, Yoo, Mi Ri, Gweon, Hye Mi, Park, Ah Young, Kim, Jeong-Ah, Youk, Ji Hyun, Moon, Hee Jung, Chang, Hang-Seok, Son, Eun Ju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939721/
https://www.ncbi.nlm.nih.gov/pubmed/27068131
http://dx.doi.org/10.14366/usg.15079
_version_ 1782442047997739008
author Eun, Na Lae
Yoo, Mi Ri
Gweon, Hye Mi
Park, Ah Young
Kim, Jeong-Ah
Youk, Ji Hyun
Moon, Hee Jung
Chang, Hang-Seok
Son, Eun Ju
author_facet Eun, Na Lae
Yoo, Mi Ri
Gweon, Hye Mi
Park, Ah Young
Kim, Jeong-Ah
Youk, Ji Hyun
Moon, Hee Jung
Chang, Hang-Seok
Son, Eun Ju
author_sort Eun, Na Lae
collection PubMed
description PURPOSE: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. METHODS: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. RESULTS: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. CONCLUSION: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules.
format Online
Article
Text
id pubmed-4939721
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-49397212016-07-12 Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up? Eun, Na Lae Yoo, Mi Ri Gweon, Hye Mi Park, Ah Young Kim, Jeong-Ah Youk, Ji Hyun Moon, Hee Jung Chang, Hang-Seok Son, Eun Ju Ultrasonography Original Article PURPOSE: The goal of this study was to assess the clinicopathologic and ultrasonographic features of thyroid nodules with nondiagnostic results on repeat ultrasonography (US)-guided fineneedle aspiration biopsy (FNAB) according to size and the number of suspicious findings and to determine the proper management of nodules with consecutive nondiagnostic results. METHODS: This retrospective study included 297 nodules with nondiagnostic results on repeat FNAB that were evaluated by US over the course of at least 12 months of follow-up, a follow-up biopsy, or an operation. We compared clinical and US variables between benign and malignant nodules in thyroid nodules with repeat nondiagnostic results. RESULTS: The comparison of benign and malignant nodules with repeat nondiagnostic results revealed that age, marked hypoechogenicity, irregular or microlobulated margins, microcalcifications, and nonparallel shape were significantly associated with malignancy. Multivariate logistic regression analysis in malignant nodules revealed that microcalcifications and irregular or microlobulated margins were independently associated with malignancy. Among them, only irregular or microlobulated margins were independently significant as a predictor of malignancy in repeatedly nondiagnostic nodules measuring >10 mm. Using receiver operating characteristic analysis, the best cutoff value for the “number of suspicious findings” between benign and malignant nodules was three in nodules of all sizes, three in nodules measuring ≤10 mm, and two in nodules measuring >10 mm. CONCLUSION: Irregular or microlobulated margins may be the most frequent US features in repeatedly nondiagnostic nodules >10 mm. The presence of “two or more suspicious findings” can be used as the cutoff for distinguishing benign and malignant nodules. Korean Society of Ultrasound in Medicine 2016-07 2016-03-06 /pmc/articles/PMC4939721/ /pubmed/27068131 http://dx.doi.org/10.14366/usg.15079 Text en Copyright © 2016 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Eun, Na Lae
Yoo, Mi Ri
Gweon, Hye Mi
Park, Ah Young
Kim, Jeong-Ah
Youk, Ji Hyun
Moon, Hee Jung
Chang, Hang-Seok
Son, Eun Ju
Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title_full Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title_fullStr Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title_full_unstemmed Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title_short Thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
title_sort thyroid nodules with nondiagnostic results on repeat fine-needle aspiration biopsy: which nodules should be considered for repeat biopsy or surgery rather than follow-up?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939721/
https://www.ncbi.nlm.nih.gov/pubmed/27068131
http://dx.doi.org/10.14366/usg.15079
work_keys_str_mv AT eunnalae thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT yoomiri thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT gweonhyemi thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT parkahyoung thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT kimjeongah thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT youkjihyun thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT moonheejung thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT changhangseok thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup
AT soneunju thyroidnoduleswithnondiagnosticresultsonrepeatfineneedleaspirationbiopsywhichnodulesshouldbeconsideredforrepeatbiopsyorsurgeryratherthanfollowup