Cargando…
Identical wave forms of vena cava and pulmonary artery during pulmonary artery catheter insertion due to kinking: a case report of a rare complication
BACKGROUND: We experienced a rare malposition of a pulmonary artery catheter due to kinking in a 63-year-old male who was scheduled for an off-pump coronary artery by-pass graft. FINDINGS: Given the difficulty to obtain stable pulmonary artery waveform, we discovered that the two waveforms of the di...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4991978/ https://www.ncbi.nlm.nih.gov/pubmed/27606155 http://dx.doi.org/10.1186/s40064-016-3050-3 |