Patients’ safety: is there a systemic release of gentamicin by gentamicin-coated tibia nails in clinical use?
INTRODUCTION: Osteitis is one of the most serious complications in orthopedic surgery. Expert Tibia Nail (ETN) PROtect™ coated with a biodegradable layer of gentamicin-laden polymer was developed for prophylaxis of osteomyelitis. In systemic administration, gentamicin has only a small therapeutic in...
Autores principales: | Moghaddam, Arash, Graeser, Viola, Westhauser, Fabian, Dapunt, Ulrike, Kamradt, Till, Woerner, Stefan M, Schmidmaier, Gerhard |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019425/ https://www.ncbi.nlm.nih.gov/pubmed/27660456 http://dx.doi.org/10.2147/TCRM.S107398 |
Ejemplares similares
-
The use of gentamicin-coated nails in the tibia: preliminary results of a prospective study
por: Fuchs, Thomas, et al.
Publicado: (2011) -
Gentamicin-Coated Tibia Nail in Fractures and Nonunion to Reduce Fracture-Related Infections: A Systematic Review
por: De Meo, Daniele, et al.
Publicado: (2020) -
Comparative study of the efficacy of gentamicin-coated intramedullary interlocking nail versus regular intramedullary interlocking nail in Gustilo type I and II open tibia fractures
por: Pinto, Deepak, et al.
Publicado: (2019) -
Use of the Suprapatellar Approach in Intramedullary Nailing of a Multi-Fragmentary Dislocated Tibia Fracture with a Hypermobile Intermediate Fragment in a Young Patient
por: Haubruck, Patrick, et al.
Publicado: (2017) -
Release rate and antimicrobial activity of gentamicin salts as coating for bone allografts
por: Coraca-Huber, DC, et al.
Publicado: (2011)