Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation

BACKGROUND: To present an intraoperative acute Descemet's fold formation using swept-source optical coherence tomography (SS-OCT) imaging. CASE REPORT: A 67-year-old man complaining of reduced visual acuity in the left eye. A 25-gauge pars plana vitrectomy combined with phacoemulsification cata...