Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation

BACKGROUND: To present an intraoperative acute Descemet's fold formation using swept-source optical coherence tomography (SS-OCT) imaging. CASE REPORT: A 67-year-old man complaining of reduced visual acuity in the left eye. A 25-gauge pars plana vitrectomy combined with phacoemulsification cata...

Descripción completa

Detalles Bibliográficos
Autores principales: Ichioka, Yu, Uji, Akihito, Yoshimura, Nagahisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5043247/
https://www.ncbi.nlm.nih.gov/pubmed/27721783
http://dx.doi.org/10.1159/000447995
_version_ 1782456717383041024
author Ichioka, Yu
Uji, Akihito
Yoshimura, Nagahisa
author_facet Ichioka, Yu
Uji, Akihito
Yoshimura, Nagahisa
author_sort Ichioka, Yu
collection PubMed
description BACKGROUND: To present an intraoperative acute Descemet's fold formation using swept-source optical coherence tomography (SS-OCT) imaging. CASE REPORT: A 67-year-old man complaining of reduced visual acuity in the left eye. A 25-gauge pars plana vitrectomy combined with phacoemulsification cataract surgery was performed to remove the vitreomacular traction. When hydro-sealing was performed, striae rapidly spread in the cornea. SS-OCT B-scan images performed on postoperative day 1 revealed a wavy Descemet's membrane that might correspond to Descemet's folds. Pairs of hypo- and hyperreflective narrow lesions running from the wavy Descemet's membrane to almost half of the thickness of the whole cornea were observed. En face OCT imaging clearly showed the stromal fold, which continuously spread from the Descemet's fold. CONCLUSION: The stromal fold might be due to the focal bulge of the stroma posteriorly caused by the rapid volume increase of the stroma which could push Descemet's membrane posteriorly, thereby forming a wavy Descemet's membrane layer.
format Online
Article
Text
id pubmed-5043247
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-50432472016-10-07 Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation Ichioka, Yu Uji, Akihito Yoshimura, Nagahisa Case Rep Ophthalmol Case Report BACKGROUND: To present an intraoperative acute Descemet's fold formation using swept-source optical coherence tomography (SS-OCT) imaging. CASE REPORT: A 67-year-old man complaining of reduced visual acuity in the left eye. A 25-gauge pars plana vitrectomy combined with phacoemulsification cataract surgery was performed to remove the vitreomacular traction. When hydro-sealing was performed, striae rapidly spread in the cornea. SS-OCT B-scan images performed on postoperative day 1 revealed a wavy Descemet's membrane that might correspond to Descemet's folds. Pairs of hypo- and hyperreflective narrow lesions running from the wavy Descemet's membrane to almost half of the thickness of the whole cornea were observed. En face OCT imaging clearly showed the stromal fold, which continuously spread from the Descemet's fold. CONCLUSION: The stromal fold might be due to the focal bulge of the stroma posteriorly caused by the rapid volume increase of the stroma which could push Descemet's membrane posteriorly, thereby forming a wavy Descemet's membrane layer. S. Karger AG 2016-07-21 /pmc/articles/PMC5043247/ /pubmed/27721783 http://dx.doi.org/10.1159/000447995 Text en Copyright © 2016 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Ichioka, Yu
Uji, Akihito
Yoshimura, Nagahisa
Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title_full Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title_fullStr Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title_full_unstemmed Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title_short Swept-Source Optical Coherence Tomography Detecting Intraoperative Acute Descemet's Fold Formation
title_sort swept-source optical coherence tomography detecting intraoperative acute descemet's fold formation
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5043247/
https://www.ncbi.nlm.nih.gov/pubmed/27721783
http://dx.doi.org/10.1159/000447995
work_keys_str_mv AT ichiokayu sweptsourceopticalcoherencetomographydetectingintraoperativeacutedescemetsfoldformation
AT ujiakihito sweptsourceopticalcoherencetomographydetectingintraoperativeacutedescemetsfoldformation
AT yoshimuranagahisa sweptsourceopticalcoherencetomographydetectingintraoperativeacutedescemetsfoldformation