Manual versus Automated Carotid Artery Plaque Component Segmentation in High and Lower Quality 3.0 Tesla MRI Scans

PURPOSE: To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. METHODS: 24 patients with 30–70% carotid artery stenosis were planned for 3T carotid MRI, followed...

Descripción completa

Detalles Bibliográficos
Autores principales: Smits, Loek P., van Wijk, Diederik F., Duivenvoorden, Raphael, Xu, Dongxiang, Yuan, Chun, Stroes, Erik S., Nederveen, Aart J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5145140/
https://www.ncbi.nlm.nih.gov/pubmed/27930665
http://dx.doi.org/10.1371/journal.pone.0164267