Role of Pulse Pressure and Geometry of Primary Entry Tear in Acute Type B Dissection Propagation

The hemodynamic and geometric factors leading to propagation of acute Type B dissections are poorly understood. The objective is to elucidate whether geometric and hemodynamic parameters increase the predilection for aortic dissection propagation. A pulse duplicator set-up was used on porcine aorta...

Descripción completa

Detalles Bibliográficos
Autores principales: Peelukhana, Srikara V., Wang, Yanmin, Berwick, Zachary, Kratzberg, Jarin, Krieger, Joshua, Roeder, Blayne, Cloughs, Rachel E., Hsiao, Albert, Chambers, Sean, Kassab, Ghassan S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5331108/
https://www.ncbi.nlm.nih.gov/pubmed/27510916
http://dx.doi.org/10.1007/s10439-016-1705-4