Cargando…

Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle

Objective: The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis. Materials and Method: Eight school going children in the age group of 11-16 years with volar Bar...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, H, Chavali, V, Daveshwar, R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333669/
https://www.ncbi.nlm.nih.gov/pubmed/28435610
http://dx.doi.org/10.5704/MOJ.1507.014