Cargando…

Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors

In order to develop a film electrode for the surface acoustic wave (SAW) devices working in high temperature, harsh environments, novel AlN/Pt/ZnO multilayers were prepared using pulsed laser deposition (PLD) systems on langasite (LGS) substrates. The AlN film was used as a protective layer and the...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Xingpeng, Peng, Bin, Zhang, Wanli, Zhu, Jun, Liu, Xingzhao, Wei, Meng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5344621/
https://www.ncbi.nlm.nih.gov/pubmed/28772429
http://dx.doi.org/10.3390/ma10010069
_version_ 1782513581032472576
author Liu, Xingpeng
Peng, Bin
Zhang, Wanli
Zhu, Jun
Liu, Xingzhao
Wei, Meng
author_facet Liu, Xingpeng
Peng, Bin
Zhang, Wanli
Zhu, Jun
Liu, Xingzhao
Wei, Meng
author_sort Liu, Xingpeng
collection PubMed
description In order to develop a film electrode for the surface acoustic wave (SAW) devices working in high temperature, harsh environments, novel AlN/Pt/ZnO multilayers were prepared using pulsed laser deposition (PLD) systems on langasite (LGS) substrates. The AlN film was used as a protective layer and the ZnO buffer layer was introduced to improve the crystal quality of Pt films. The results show that the resistances of Pt and AlN/Pt film electrodes violently increase above 600 °C and 800 °C, respectively, while the resistances of AlN/Pt/ZnO electrodes have more stable electrical resistance from room temperature to 1000 °C. The AlN/Pt/ZnO electrode, where the ZnO film was deposited at 600 °C, has the best temperature stability and can steadily work for 4 h at 1000 °C. The mechanism underlying the stable resistance of the AlN/Pt/ZnO electrode at a high temperature was investigated by analyzing the microstructure of the prepared samples. The proposed AlN/Pt/ZnO film electrode has great potential for applications in high temperature SAW sensors.
format Online
Article
Text
id pubmed-5344621
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53446212017-07-28 Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors Liu, Xingpeng Peng, Bin Zhang, Wanli Zhu, Jun Liu, Xingzhao Wei, Meng Materials (Basel) Article In order to develop a film electrode for the surface acoustic wave (SAW) devices working in high temperature, harsh environments, novel AlN/Pt/ZnO multilayers were prepared using pulsed laser deposition (PLD) systems on langasite (LGS) substrates. The AlN film was used as a protective layer and the ZnO buffer layer was introduced to improve the crystal quality of Pt films. The results show that the resistances of Pt and AlN/Pt film electrodes violently increase above 600 °C and 800 °C, respectively, while the resistances of AlN/Pt/ZnO electrodes have more stable electrical resistance from room temperature to 1000 °C. The AlN/Pt/ZnO electrode, where the ZnO film was deposited at 600 °C, has the best temperature stability and can steadily work for 4 h at 1000 °C. The mechanism underlying the stable resistance of the AlN/Pt/ZnO electrode at a high temperature was investigated by analyzing the microstructure of the prepared samples. The proposed AlN/Pt/ZnO film electrode has great potential for applications in high temperature SAW sensors. MDPI 2017-01-16 /pmc/articles/PMC5344621/ /pubmed/28772429 http://dx.doi.org/10.3390/ma10010069 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Xingpeng
Peng, Bin
Zhang, Wanli
Zhu, Jun
Liu, Xingzhao
Wei, Meng
Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title_full Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title_fullStr Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title_full_unstemmed Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title_short Novel AlN/Pt/ZnO Electrode for High Temperature SAW Sensors
title_sort novel aln/pt/zno electrode for high temperature saw sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5344621/
https://www.ncbi.nlm.nih.gov/pubmed/28772429
http://dx.doi.org/10.3390/ma10010069
work_keys_str_mv AT liuxingpeng novelalnptznoelectrodeforhightemperaturesawsensors
AT pengbin novelalnptznoelectrodeforhightemperaturesawsensors
AT zhangwanli novelalnptznoelectrodeforhightemperaturesawsensors
AT zhujun novelalnptznoelectrodeforhightemperaturesawsensors
AT liuxingzhao novelalnptznoelectrodeforhightemperaturesawsensors
AT weimeng novelalnptznoelectrodeforhightemperaturesawsensors