Cargando…
Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish
RATIONALE: Domoic acid (DA) is a potent neurotoxin that accumulates in shellfish. Routine testing involves homogenization, extraction and chromatographic analysis, with a run time of up to 30 min. Improving throughput using ambient ionization for direct analysis of DA in tissue would result in signi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434922/ https://www.ncbi.nlm.nih.gov/pubmed/27534707 http://dx.doi.org/10.1002/rcm.7725 |
_version_ | 1783237141686386688 |
---|---|
author | Beach, Daniel G. Walsh, Callee M. Cantrell, Pamela Rourke, Wade O'Brien, Sinead Reeves, Kelley McCarron, Pearse |
author_facet | Beach, Daniel G. Walsh, Callee M. Cantrell, Pamela Rourke, Wade O'Brien, Sinead Reeves, Kelley McCarron, Pearse |
author_sort | Beach, Daniel G. |
collection | PubMed |
description | RATIONALE: Domoic acid (DA) is a potent neurotoxin that accumulates in shellfish. Routine testing involves homogenization, extraction and chromatographic analysis, with a run time of up to 30 min. Improving throughput using ambient ionization for direct analysis of DA in tissue would result in significant time savings for regulatory testing labs. METHODS: We assess the suitability of laser ablation electrospray ionization high‐resolution mass spectrometry (LAESI‐HRMS) for high‐throughput screening or quantitation of DA in a variety of shellfish matrices. The method was first optimized for use with HRMS detection. Challenges such as tissue sub‐sampling, isobaric interferences and method calibration were considered and practical solutions developed. Samples included 189 real shellfish samples previously analyzed by regulatory labs as well as mussel matrix certified reference materials. RESULTS: Domoic acid was selectively analyzed directly from shellfish tissue homogenates with a run time of 12 s. The limits of detection were between 0.24 and 1.6 mg DA kg(−1) tissue, similar to those of LC/UV methods. The precision was between 27 and 44% relative standard deviation (RSD), making the technique more suited to screening than direct quantitation. LAESI‐MS showed good agreement with LC/UV and LC/MS and was capable of identifying samples above and below 5 mg DA kg(−1) wet shellfish tissue, one quarter of the regulatory limit. CONCLUSIONS: These findings demonstrate the suitability of LAESI‐MS for routine, high‐throughput screening of DA. This approach could result in significant time savings for regulatory labs carrying out shellfish safety testing on thousands of samples annually. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. |
format | Online Article Text |
id | pubmed-5434922 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-54349222017-06-01 Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish Beach, Daniel G. Walsh, Callee M. Cantrell, Pamela Rourke, Wade O'Brien, Sinead Reeves, Kelley McCarron, Pearse Rapid Commun Mass Spectrom Research Articles RATIONALE: Domoic acid (DA) is a potent neurotoxin that accumulates in shellfish. Routine testing involves homogenization, extraction and chromatographic analysis, with a run time of up to 30 min. Improving throughput using ambient ionization for direct analysis of DA in tissue would result in significant time savings for regulatory testing labs. METHODS: We assess the suitability of laser ablation electrospray ionization high‐resolution mass spectrometry (LAESI‐HRMS) for high‐throughput screening or quantitation of DA in a variety of shellfish matrices. The method was first optimized for use with HRMS detection. Challenges such as tissue sub‐sampling, isobaric interferences and method calibration were considered and practical solutions developed. Samples included 189 real shellfish samples previously analyzed by regulatory labs as well as mussel matrix certified reference materials. RESULTS: Domoic acid was selectively analyzed directly from shellfish tissue homogenates with a run time of 12 s. The limits of detection were between 0.24 and 1.6 mg DA kg(−1) tissue, similar to those of LC/UV methods. The precision was between 27 and 44% relative standard deviation (RSD), making the technique more suited to screening than direct quantitation. LAESI‐MS showed good agreement with LC/UV and LC/MS and was capable of identifying samples above and below 5 mg DA kg(−1) wet shellfish tissue, one quarter of the regulatory limit. CONCLUSIONS: These findings demonstrate the suitability of LAESI‐MS for routine, high‐throughput screening of DA. This approach could result in significant time savings for regulatory labs carrying out shellfish safety testing on thousands of samples annually. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. John Wiley and Sons Inc. 2016-10-10 2016-11-30 /pmc/articles/PMC5434922/ /pubmed/27534707 http://dx.doi.org/10.1002/rcm.7725 Text en © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Beach, Daniel G. Walsh, Callee M. Cantrell, Pamela Rourke, Wade O'Brien, Sinead Reeves, Kelley McCarron, Pearse Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title | Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title_full | Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title_fullStr | Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title_full_unstemmed | Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title_short | Laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
title_sort | laser ablation electrospray ionization high‐resolution mass spectrometry for regulatory screening of domoic acid in shellfish |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434922/ https://www.ncbi.nlm.nih.gov/pubmed/27534707 http://dx.doi.org/10.1002/rcm.7725 |
work_keys_str_mv | AT beachdanielg laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT walshcalleem laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT cantrellpamela laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT rourkewade laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT obriensinead laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT reeveskelley laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish AT mccarronpearse laserablationelectrosprayionizationhighresolutionmassspectrometryforregulatoryscreeningofdomoicacidinshellfish |