Cargando…
Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry
Rapid and sensitive detection of botulinum neurotoxins (BoNTs), which cause botulism, is essential in a public health emergency or bioterrorism event. We have previously developed a mass spectrometry (MS)-based functional method, Endopep-MS assay, for the fast detection and differentiation of all Bo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519644/ https://www.ncbi.nlm.nih.gov/pubmed/28573317 http://dx.doi.org/10.1007/s00216-017-0421-8 |
_version_ | 1783251661367541760 |
---|---|
author | Wang, Dongxia Baudys, Jakub Hoyt, Kaitlin M. Barr, John R. Kalb, Suzanne R. |
author_facet | Wang, Dongxia Baudys, Jakub Hoyt, Kaitlin M. Barr, John R. Kalb, Suzanne R. |
author_sort | Wang, Dongxia |
collection | PubMed |
description | Rapid and sensitive detection of botulinum neurotoxins (BoNTs), which cause botulism, is essential in a public health emergency or bioterrorism event. We have previously developed a mass spectrometry (MS)-based functional method, Endopep-MS assay, for the fast detection and differentiation of all BoNT serotypes by affinity enriching the toxin and detecting the serotype-specific cleavage products of peptide substrates derived from the in vivo targets. To improve the performance of the Endopep-MS assay, we report here the further optimization of the peptide substrate for the detection of serotype A botulinum neurotoxins. An increased substrate cleavage was achieved by extending the original peptide N-terminus with optimized amino acid sequence, increasing the detection sensitivity of the method. In addition, the resistance of the substrate to nonspecific hydrolysis was dramatically improved by selectively substituting amino acids at the scissile bond and various other positions of the extended peptide. Moreover, incorporating the N-terminal hydrophobic residues dramatically improved the relative intensity of the cleavage products in the mass spectra. This allowed easy detection of the cleavage products, further enhancing the performance of the assay. The limit of detection for spiked serum sample was enhanced from 0.5 to 0.1 mouseLD(50) and from 0.5 to 0.2 mouseLD(50) for spiked stool. [Figure: see text] |
format | Online Article Text |
id | pubmed-5519644 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-55196442017-08-07 Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry Wang, Dongxia Baudys, Jakub Hoyt, Kaitlin M. Barr, John R. Kalb, Suzanne R. Anal Bioanal Chem Research Paper Rapid and sensitive detection of botulinum neurotoxins (BoNTs), which cause botulism, is essential in a public health emergency or bioterrorism event. We have previously developed a mass spectrometry (MS)-based functional method, Endopep-MS assay, for the fast detection and differentiation of all BoNT serotypes by affinity enriching the toxin and detecting the serotype-specific cleavage products of peptide substrates derived from the in vivo targets. To improve the performance of the Endopep-MS assay, we report here the further optimization of the peptide substrate for the detection of serotype A botulinum neurotoxins. An increased substrate cleavage was achieved by extending the original peptide N-terminus with optimized amino acid sequence, increasing the detection sensitivity of the method. In addition, the resistance of the substrate to nonspecific hydrolysis was dramatically improved by selectively substituting amino acids at the scissile bond and various other positions of the extended peptide. Moreover, incorporating the N-terminal hydrophobic residues dramatically improved the relative intensity of the cleavage products in the mass spectra. This allowed easy detection of the cleavage products, further enhancing the performance of the assay. The limit of detection for spiked serum sample was enhanced from 0.5 to 0.1 mouseLD(50) and from 0.5 to 0.2 mouseLD(50) for spiked stool. [Figure: see text] Springer Berlin Heidelberg 2017-06-02 2017 /pmc/articles/PMC5519644/ /pubmed/28573317 http://dx.doi.org/10.1007/s00216-017-0421-8 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Paper Wang, Dongxia Baudys, Jakub Hoyt, Kaitlin M. Barr, John R. Kalb, Suzanne R. Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title | Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title_full | Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title_fullStr | Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title_full_unstemmed | Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title_short | Further optimization of peptide substrate enhanced assay performance for BoNT/A detection by MALDI-TOF mass spectrometry |
title_sort | further optimization of peptide substrate enhanced assay performance for bont/a detection by maldi-tof mass spectrometry |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519644/ https://www.ncbi.nlm.nih.gov/pubmed/28573317 http://dx.doi.org/10.1007/s00216-017-0421-8 |
work_keys_str_mv | AT wangdongxia furtheroptimizationofpeptidesubstrateenhancedassayperformanceforbontadetectionbymalditofmassspectrometry AT baudysjakub furtheroptimizationofpeptidesubstrateenhancedassayperformanceforbontadetectionbymalditofmassspectrometry AT hoytkaitlinm furtheroptimizationofpeptidesubstrateenhancedassayperformanceforbontadetectionbymalditofmassspectrometry AT barrjohnr furtheroptimizationofpeptidesubstrateenhancedassayperformanceforbontadetectionbymalditofmassspectrometry AT kalbsuzanner furtheroptimizationofpeptidesubstrateenhancedassayperformanceforbontadetectionbymalditofmassspectrometry |