Cargando…
26-G needle-assisted sutureless glueless intrascleral haptic fixation for secondary ciliary sulcus implantation of three-piece polymethylmethacrylate intraocular lens during penetrating keratoplasty
After tenotomy adjoining 3 o’clock and 9 o’clock limbus, 3-mm-wide partial-thickness scleral tunnels are created at these two diametrically opposite points 3 mm from the limbus such that they reach up to a distance of 1.5 mm from the limbus. Two ab externo sclerotomies are created using 26-G needles...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5525618/ https://www.ncbi.nlm.nih.gov/pubmed/29018730 http://dx.doi.org/10.1016/j.tjo.2016.04.008 |