Cargando…

Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection

The need for rapid and efficient high throughput metabolic phenotyping (metabotyping) in metabolomic/metabonomic studies often requires compromises to be made between analytical speed and metabolome coverage. Here the effect of column length (150, 75 and 30 mm) and gradient duration (15, 7.5 and 3 m...

Descripción completa

Detalles Bibliográficos
Autores principales: Rainville, Paul D., Wilson, Ian D., Nicholson, Jeremy K., Issacs, Giorgis, Mullin, Lauren, Langridge, James I., Plumb, Robert S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5533171/
https://www.ncbi.nlm.nih.gov/pubmed/28734348
http://dx.doi.org/10.1016/j.aca.2017.06.020
_version_ 1783253588454146048
author Rainville, Paul D.
Wilson, Ian D.
Nicholson, Jeremy K.
Issacs, Giorgis
Mullin, Lauren
Langridge, James I.
Plumb, Robert S.
author_facet Rainville, Paul D.
Wilson, Ian D.
Nicholson, Jeremy K.
Issacs, Giorgis
Mullin, Lauren
Langridge, James I.
Plumb, Robert S.
author_sort Rainville, Paul D.
collection PubMed
description The need for rapid and efficient high throughput metabolic phenotyping (metabotyping) in metabolomic/metabonomic studies often requires compromises to be made between analytical speed and metabolome coverage. Here the effect of column length (150, 75 and 30 mm) and gradient duration (15, 7.5 and 3 min respectively) on the number of features detected when untargeted metabolic profiling of human urine using reversed-phase gradient ultra performance chromatography with, and without, ion mobility spectrometry, has been examined. As would be expected, reducing column length from 150 to 30 mm, and gradient duration, from 15 to 3 min, resulted in a reduction in peak capacity from 311 to 63 and a similar reduction in the number of features detected from over ca. 16,000 to ca. 6500. Under the same chromatographic conditions employing UPLC/IMS/MS to provide an additional orthogonal separation resulted in an increase in the number of MS features detected to nearly 20,000 and ca. 7500 for the 150 mm and the 30 mm columns respectively. Based on this limited study the potential of LC/IMS/MS as a tool for improving throughput and increasing metabolome coverage clearly merits further in depth study.
format Online
Article
Text
id pubmed-5533171
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55331712017-08-22 Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection Rainville, Paul D. Wilson, Ian D. Nicholson, Jeremy K. Issacs, Giorgis Mullin, Lauren Langridge, James I. Plumb, Robert S. Anal Chim Acta Article The need for rapid and efficient high throughput metabolic phenotyping (metabotyping) in metabolomic/metabonomic studies often requires compromises to be made between analytical speed and metabolome coverage. Here the effect of column length (150, 75 and 30 mm) and gradient duration (15, 7.5 and 3 min respectively) on the number of features detected when untargeted metabolic profiling of human urine using reversed-phase gradient ultra performance chromatography with, and without, ion mobility spectrometry, has been examined. As would be expected, reducing column length from 150 to 30 mm, and gradient duration, from 15 to 3 min, resulted in a reduction in peak capacity from 311 to 63 and a similar reduction in the number of features detected from over ca. 16,000 to ca. 6500. Under the same chromatographic conditions employing UPLC/IMS/MS to provide an additional orthogonal separation resulted in an increase in the number of MS features detected to nearly 20,000 and ca. 7500 for the 150 mm and the 30 mm columns respectively. Based on this limited study the potential of LC/IMS/MS as a tool for improving throughput and increasing metabolome coverage clearly merits further in depth study. Elsevier 2017-08-22 /pmc/articles/PMC5533171/ /pubmed/28734348 http://dx.doi.org/10.1016/j.aca.2017.06.020 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rainville, Paul D.
Wilson, Ian D.
Nicholson, Jeremy K.
Issacs, Giorgis
Mullin, Lauren
Langridge, James I.
Plumb, Robert S.
Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title_full Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title_fullStr Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title_full_unstemmed Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title_short Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
title_sort ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5533171/
https://www.ncbi.nlm.nih.gov/pubmed/28734348
http://dx.doi.org/10.1016/j.aca.2017.06.020
work_keys_str_mv AT rainvillepauld ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT wilsoniand ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT nicholsonjeremyk ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT issacsgiorgis ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT mullinlauren ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT langridgejamesi ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection
AT plumbroberts ionmobilityspectrometrycombinedwithultraperformanceliquidchromatographymassspectrometryformetabolicphenotypingofurineeffectsofcolumnlengthgradientdurationandionmobilityspectrometryonmetabolitedetection