Cargando…

Extraocular needle- guided haptic insertion technique of scleral fixation intraocular lens surgeries (X-NIT)

The most challenging step in sutureless scleral fixation of intraocular lens (SFIOL) is exteriorization of haptics. The conventional handshake technique has a learning curve since it involves intraocular handing over of haptics from one forceps to another. Here, we describe “extraocular needle-guide...

Descripción completa

Detalles Bibliográficos
Autores principales: Baskaran, Prabu, Ganne, Pratyusha, Bhandari, Sahil, Ramakrishnan, Seema, Venkatesh, Rengaraj, Gireesh, Prashant
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5598190/
https://www.ncbi.nlm.nih.gov/pubmed/28820165
http://dx.doi.org/10.4103/ijo.IJO_296_17