Cargando…

Posterior pole retinal detachment due to a macular hole in a patient with a Boston Keratoprosthesis

PURPOSE: To describe the clinical course of a patient with a Boston Keratoprosthesis type I who developed a localized posterior pole retinal detachment secondary to a macular hole. OBSERVATIONS: A 73-year-old patient with a Boston Keratoprosthesis developed a localized posterior pole retinal detachm...

Descripción completa

Detalles Bibliográficos
Autores principales: Gologorsky, Daniel, Williams, Basil K., Flynn, Harry W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5607640/
https://www.ncbi.nlm.nih.gov/pubmed/28944307
http://dx.doi.org/10.1016/j.ajoc.2016.12.001