Cargando…

High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence

BACKGROUND: Historically, mRNA measurements have been tested on several commercially available platforms, but none have gained broad acceptance for assessment of HER2. An mRNA measurement, as a continuous value, has the potential for use in adjudication of the equivocal category. Here we use a real-...

Descripción completa

Detalles Bibliográficos
Autores principales: Wasserman, Brad E., Carvajal-Hausdorf, Daniel E., Ho, Kenneth, Wong, Wendy, Wu, Natalie, Chu, Victor C., Lai, Edwin W., Weidler, Jodi M., Bates, Michael, Neumeister, Veronique, Rimm, David L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711560/
https://www.ncbi.nlm.nih.gov/pubmed/28892092
http://dx.doi.org/10.1038/labinvest.2017.93
_version_ 1783283066216644608
author Wasserman, Brad E.
Carvajal-Hausdorf, Daniel E.
Ho, Kenneth
Wong, Wendy
Wu, Natalie
Chu, Victor C.
Lai, Edwin W.
Weidler, Jodi M.
Bates, Michael
Neumeister, Veronique
Rimm, David L.
author_facet Wasserman, Brad E.
Carvajal-Hausdorf, Daniel E.
Ho, Kenneth
Wong, Wendy
Wu, Natalie
Chu, Victor C.
Lai, Edwin W.
Weidler, Jodi M.
Bates, Michael
Neumeister, Veronique
Rimm, David L.
author_sort Wasserman, Brad E.
collection PubMed
description BACKGROUND: Historically, mRNA measurements have been tested on several commercially available platforms, but none have gained broad acceptance for assessment of HER2. An mRNA measurement, as a continuous value, has the potential for use in adjudication of the equivocal category. Here we use a real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) assay in a closed, single-use cartridge, automated system. METHODS: Multiple cores (1mm in diameter) were retrospectively collected from 80 formalin-fixed paraffin-embedded (FFPE) tissue blocks with invasive breast cancer seen by Yale Pathology Labs between 1998 and 2011. Tissue cores were processed with a FFPE lysis kit to create lysates that were tested with the automated RT-qPCR assay. Results for IHC and FISH were extracted from the pathology reports and quantitative immunofluorescence (QIF) for each case was measured as previously described. RESULTS: Quality control testing showed that the GX platform RT-qPCR shows no case to case cross contamination on material from routine histology practices. Concordance between RT-qPCR and IHC/FISH was 91.25% (sensitivity = 0.87; specificity = 0.94; PPV = 0.89; NPV = 0.92) using a pre-defined delta Ct cut-off (dCt ≥ −1) for HER2. Concordance (OPA) between RT-qPCR and QIF was 94% (sensitivity = 0.90; specificity = 0.96; PPV = 0.93; NPV = 0.94) using dCt ≥ −1 and a previously defined cut-point for positivity by QIF. CONCLUSIONS: The closed system RT-qPCR assay shows greater than 90% concordance with the ASCO/CAP HER2 IHC/FISH scoring. Additionally, the RT-qPCR assay is highly concordant (94%) with the continuous variable HER2 QIF assay, and may better reflect the true continuum of HER2 receptor status in invasive breast cancer. These initial results suggest that fast, closed system molecular assays may have future value for the adjudication of the ASCO/CAP HER2 equivocal category or possibly routine usage in time constrained or low resource settings.
format Online
Article
Text
id pubmed-5711560
institution National Center for Biotechnology Information
language English
publishDate 2017
record_format MEDLINE/PubMed
spelling pubmed-57115602018-03-11 High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence Wasserman, Brad E. Carvajal-Hausdorf, Daniel E. Ho, Kenneth Wong, Wendy Wu, Natalie Chu, Victor C. Lai, Edwin W. Weidler, Jodi M. Bates, Michael Neumeister, Veronique Rimm, David L. Lab Invest Article BACKGROUND: Historically, mRNA measurements have been tested on several commercially available platforms, but none have gained broad acceptance for assessment of HER2. An mRNA measurement, as a continuous value, has the potential for use in adjudication of the equivocal category. Here we use a real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) assay in a closed, single-use cartridge, automated system. METHODS: Multiple cores (1mm in diameter) were retrospectively collected from 80 formalin-fixed paraffin-embedded (FFPE) tissue blocks with invasive breast cancer seen by Yale Pathology Labs between 1998 and 2011. Tissue cores were processed with a FFPE lysis kit to create lysates that were tested with the automated RT-qPCR assay. Results for IHC and FISH were extracted from the pathology reports and quantitative immunofluorescence (QIF) for each case was measured as previously described. RESULTS: Quality control testing showed that the GX platform RT-qPCR shows no case to case cross contamination on material from routine histology practices. Concordance between RT-qPCR and IHC/FISH was 91.25% (sensitivity = 0.87; specificity = 0.94; PPV = 0.89; NPV = 0.92) using a pre-defined delta Ct cut-off (dCt ≥ −1) for HER2. Concordance (OPA) between RT-qPCR and QIF was 94% (sensitivity = 0.90; specificity = 0.96; PPV = 0.93; NPV = 0.94) using dCt ≥ −1 and a previously defined cut-point for positivity by QIF. CONCLUSIONS: The closed system RT-qPCR assay shows greater than 90% concordance with the ASCO/CAP HER2 IHC/FISH scoring. Additionally, the RT-qPCR assay is highly concordant (94%) with the continuous variable HER2 QIF assay, and may better reflect the true continuum of HER2 receptor status in invasive breast cancer. These initial results suggest that fast, closed system molecular assays may have future value for the adjudication of the ASCO/CAP HER2 equivocal category or possibly routine usage in time constrained or low resource settings. 2017-09-11 2017-12 /pmc/articles/PMC5711560/ /pubmed/28892092 http://dx.doi.org/10.1038/labinvest.2017.93 Text en Users may view, print, copy, and download text and data-mine the content in such documents, for the purposes of academic research, subject always to the full Conditions of use: http://www.nature.com/authors/editorial_policies/license.html#terms
spellingShingle Article
Wasserman, Brad E.
Carvajal-Hausdorf, Daniel E.
Ho, Kenneth
Wong, Wendy
Wu, Natalie
Chu, Victor C.
Lai, Edwin W.
Weidler, Jodi M.
Bates, Michael
Neumeister, Veronique
Rimm, David L.
High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title_full High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title_fullStr High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title_full_unstemmed High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title_short High Concordance of a Closed-System, RT-qPCR Breast Cancer Assay for HER2 mRNA, Compared to Clinically Determined Immunohistochemistry, Fluorescence in situ Hybridization, and Quantitative Immunofluorescence
title_sort high concordance of a closed-system, rt-qpcr breast cancer assay for her2 mrna, compared to clinically determined immunohistochemistry, fluorescence in situ hybridization, and quantitative immunofluorescence
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711560/
https://www.ncbi.nlm.nih.gov/pubmed/28892092
http://dx.doi.org/10.1038/labinvest.2017.93
work_keys_str_mv AT wassermanbrade highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT carvajalhausdorfdaniele highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT hokenneth highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT wongwendy highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT wunatalie highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT chuvictorc highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT laiedwinw highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT weidlerjodim highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT batesmichael highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT neumeisterveronique highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence
AT rimmdavidl highconcordanceofaclosedsystemrtqpcrbreastcancerassayforher2mrnacomparedtoclinicallydeterminedimmunohistochemistryfluorescenceinsituhybridizationandquantitativeimmunofluorescence