Cargando…

Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)

Before implementing one of two new LVEF radionuclide gated ventriculogram (MUGA) systems, the results from 312 consecutive parallel patient studies were evaluated. Each gamma‐camera acquisition was simultaneously processed by semi‐automatic Medasys Pinnacle and by fully automatic and semiautomatic P...

Descripción completa

Detalles Bibliográficos
Autores principales: Fair, Joanna R., Heintz, Philip H., Telepak, Robert J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720542/
https://www.ncbi.nlm.nih.gov/pubmed/19692979
http://dx.doi.org/10.1120/jacmp.v10i3.2977
_version_ 1783284670812651520
author Fair, Joanna R.
Heintz, Philip H.
Telepak, Robert J.
author_facet Fair, Joanna R.
Heintz, Philip H.
Telepak, Robert J.
author_sort Fair, Joanna R.
collection PubMed
description Before implementing one of two new LVEF radionuclide gated ventriculogram (MUGA) systems, the results from 312 consecutive parallel patient studies were evaluated. Each gamma‐camera acquisition was simultaneously processed by semi‐automatic Medasys Pinnacle and by fully automatic and semiautomatic Philips nuclear medicine computer systems. The Philips systems yielded LVEF results within [Formula: see text] percentage points of the Medasys system in fewer than half of the studies. The remaining values were higher or lower than those from the long‐used Medasys system. These differences might have changed cancer patient chemotherapy clinical decisions. As a result, our institution elected not to implement either new system. PACS: 87.57.U‐ Nuclear medicine imaging
format Online
Article
Text
id pubmed-5720542
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57205422018-04-02 Evaluation of new data processing algorithms for planar gated ventriculography (MUGA) Fair, Joanna R. Heintz, Philip H. Telepak, Robert J. J Appl Clin Med Phys Medical Imaging Before implementing one of two new LVEF radionuclide gated ventriculogram (MUGA) systems, the results from 312 consecutive parallel patient studies were evaluated. Each gamma‐camera acquisition was simultaneously processed by semi‐automatic Medasys Pinnacle and by fully automatic and semiautomatic Philips nuclear medicine computer systems. The Philips systems yielded LVEF results within [Formula: see text] percentage points of the Medasys system in fewer than half of the studies. The remaining values were higher or lower than those from the long‐used Medasys system. These differences might have changed cancer patient chemotherapy clinical decisions. As a result, our institution elected not to implement either new system. PACS: 87.57.U‐ Nuclear medicine imaging John Wiley and Sons Inc. 2009-07-08 /pmc/articles/PMC5720542/ /pubmed/19692979 http://dx.doi.org/10.1120/jacmp.v10i3.2977 Text en © 2009 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Fair, Joanna R.
Heintz, Philip H.
Telepak, Robert J.
Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title_full Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title_fullStr Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title_full_unstemmed Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title_short Evaluation of new data processing algorithms for planar gated ventriculography (MUGA)
title_sort evaluation of new data processing algorithms for planar gated ventriculography (muga)
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720542/
https://www.ncbi.nlm.nih.gov/pubmed/19692979
http://dx.doi.org/10.1120/jacmp.v10i3.2977
work_keys_str_mv AT fairjoannar evaluationofnewdataprocessingalgorithmsforplanargatedventriculographymuga
AT heintzphiliph evaluationofnewdataprocessingalgorithmsforplanargatedventriculographymuga
AT telepakrobertj evaluationofnewdataprocessingalgorithmsforplanargatedventriculographymuga