Cargando…

A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors

This report presents an analysis of patient setup errors resulting from inaccurately positioned wall lasers. It suggests that laser beams should agree within 0.2 degree or better with the machine axes that they are delineating. For typical simulator and treatment rooms having wall‐to‐isocenter dista...

Descripción completa

Detalles Bibliográficos
Autores principales: Brezovich, Ivan A., Jordan, Stephen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722625/
https://www.ncbi.nlm.nih.gov/pubmed/18449147
http://dx.doi.org/10.1120/jacmp.v8i4.2398
_version_ 1783285058248900608
author Brezovich, Ivan A.
Jordan, Stephen
author_facet Brezovich, Ivan A.
Jordan, Stephen
author_sort Brezovich, Ivan A.
collection PubMed
description This report presents an analysis of patient setup errors resulting from inaccurately positioned wall lasers. It suggests that laser beams should agree within 0.2 degree or better with the machine axes that they are delineating. For typical simulator and treatment rooms having wall‐to‐isocenter distances of 3 m, this requirement is satisfied when the beam‐emitting aperture is mounted within about 1.0 cm from the intersection of the respective machine axis with the wall. To achieve the required precision, we developed and clinically tested a simple, inexpensive tool, the Laser Placer (LP). The essential component of the LP is a cube with mirror surfaces that is aligned with the machine axes using built‐in spirit levels and the light field and crosshairs of the collimator. Wall, ceiling, and sagittal lasers are installed and aligned according to reflections of their beams by the cube, and reference lines provided by the LP. Measurements showed that, even in new accelerator installations performed by highly experienced technicians, wall lasers are often mounted off target by more than 1.5 cm. Such inaccuracies can contribute systematic errors of 2 mm or more to the random setup errors attributable to interfraction movement in patient anatomy. To keep setup errors to a minimum, medical physicists should check beam orthogonality in addition to beam congruence at isocenter as recommended by the TG‐40 quality assurance protocol from the American Association of Physicists in Medicine. PACS number: 87.53.‐j
format Online
Article
Text
id pubmed-5722625
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-57226252018-04-02 A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors Brezovich, Ivan A. Jordan, Stephen J Appl Clin Med Phys Radiation Oncology Physics This report presents an analysis of patient setup errors resulting from inaccurately positioned wall lasers. It suggests that laser beams should agree within 0.2 degree or better with the machine axes that they are delineating. For typical simulator and treatment rooms having wall‐to‐isocenter distances of 3 m, this requirement is satisfied when the beam‐emitting aperture is mounted within about 1.0 cm from the intersection of the respective machine axis with the wall. To achieve the required precision, we developed and clinically tested a simple, inexpensive tool, the Laser Placer (LP). The essential component of the LP is a cube with mirror surfaces that is aligned with the machine axes using built‐in spirit levels and the light field and crosshairs of the collimator. Wall, ceiling, and sagittal lasers are installed and aligned according to reflections of their beams by the cube, and reference lines provided by the LP. Measurements showed that, even in new accelerator installations performed by highly experienced technicians, wall lasers are often mounted off target by more than 1.5 cm. Such inaccuracies can contribute systematic errors of 2 mm or more to the random setup errors attributable to interfraction movement in patient anatomy. To keep setup errors to a minimum, medical physicists should check beam orthogonality in addition to beam congruence at isocenter as recommended by the TG‐40 quality assurance protocol from the American Association of Physicists in Medicine. PACS number: 87.53.‐j John Wiley and Sons Inc. 2007-10-10 /pmc/articles/PMC5722625/ /pubmed/18449147 http://dx.doi.org/10.1120/jacmp.v8i4.2398 Text en © 2007 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Brezovich, Ivan A.
Jordan, Stephen
A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title_full A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title_fullStr A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title_full_unstemmed A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title_short A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
title_sort device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5722625/
https://www.ncbi.nlm.nih.gov/pubmed/18449147
http://dx.doi.org/10.1120/jacmp.v8i4.2398
work_keys_str_mv AT brezovichivana adeviceforprecisionpositioningandalignmentofroomlaserstodiminishtheircontributiontopatientsetuperrors
AT jordanstephen adeviceforprecisionpositioningandalignmentofroomlaserstodiminishtheircontributiontopatientsetuperrors
AT brezovichivana deviceforprecisionpositioningandalignmentofroomlaserstodiminishtheircontributiontopatientsetuperrors
AT jordanstephen deviceforprecisionpositioningandalignmentofroomlaserstodiminishtheircontributiontopatientsetuperrors