Cargando…
Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760819/ https://www.ncbi.nlm.nih.gov/pubmed/29403722 http://dx.doi.org/10.1016/j.jpha.2011.09.005 |
_version_ | 1783291441939742720 |
---|---|
author | Zheng, Rong Wu, Yi-Hong Jiang, De-Xi Zhang, Dan |
author_facet | Zheng, Rong Wu, Yi-Hong Jiang, De-Xi Zhang, Dan |
author_sort | Zheng, Rong |
collection | PubMed |
description | A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers. |
format | Online Article Text |
id | pubmed-5760819 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57608192018-02-05 Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies Zheng, Rong Wu, Yi-Hong Jiang, De-Xi Zhang, Dan J Pharm Anal Article A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers. Xi'an Jiaotong University 2012-02 2012-01-04 /pmc/articles/PMC5760819/ /pubmed/29403722 http://dx.doi.org/10.1016/j.jpha.2011.09.005 Text en © 2012 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/). |
spellingShingle | Article Zheng, Rong Wu, Yi-Hong Jiang, De-Xi Zhang, Dan Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title | Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title_full | Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title_fullStr | Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title_full_unstemmed | Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title_short | Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
title_sort | determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760819/ https://www.ncbi.nlm.nih.gov/pubmed/29403722 http://dx.doi.org/10.1016/j.jpha.2011.09.005 |
work_keys_str_mv | AT zhengrong determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies AT wuyihong determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies AT jiangdexi determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies AT zhangdan determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies |