Cargando…

Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies

A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Rong, Wu, Yi-Hong, Jiang, De-Xi, Zhang, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760819/
https://www.ncbi.nlm.nih.gov/pubmed/29403722
http://dx.doi.org/10.1016/j.jpha.2011.09.005
_version_ 1783291441939742720
author Zheng, Rong
Wu, Yi-Hong
Jiang, De-Xi
Zhang, Dan
author_facet Zheng, Rong
Wu, Yi-Hong
Jiang, De-Xi
Zhang, Dan
author_sort Zheng, Rong
collection PubMed
description A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers.
format Online
Article
Text
id pubmed-5760819
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57608192018-02-05 Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies Zheng, Rong Wu, Yi-Hong Jiang, De-Xi Zhang, Dan J Pharm Anal Article A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers. Xi'an Jiaotong University 2012-02 2012-01-04 /pmc/articles/PMC5760819/ /pubmed/29403722 http://dx.doi.org/10.1016/j.jpha.2011.09.005 Text en © 2012 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Zheng, Rong
Wu, Yi-Hong
Jiang, De-Xi
Zhang, Dan
Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title_full Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title_fullStr Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title_full_unstemmed Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title_short Determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
title_sort determination of metabolite of nicergoline in human plasma by high-performance liquid chromatography and its application in pharmacokinetic studies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760819/
https://www.ncbi.nlm.nih.gov/pubmed/29403722
http://dx.doi.org/10.1016/j.jpha.2011.09.005
work_keys_str_mv AT zhengrong determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies
AT wuyihong determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies
AT jiangdexi determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies
AT zhangdan determinationofmetaboliteofnicergolineinhumanplasmabyhighperformanceliquidchromatographyanditsapplicationinpharmacokineticstudies