Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation

A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide, Imp-A, Imp-B, Imp-D, Imp-E, and Imp-F) in a laboratory mixture as well as in a novel tablet for...

Descripción completa

Detalles Bibliográficos
Autores principales: Chatpalliwar, Vivekanand A., Porwal, Pawan K., Upmanyu, Neeraj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Xi'an Jiaotong University 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760901/
https://www.ncbi.nlm.nih.gov/pubmed/29403747
http://dx.doi.org/10.1016/j.jpha.2012.01.003
_version_ 1783291461259755520
author Chatpalliwar, Vivekanand A.
Porwal, Pawan K.
Upmanyu, Neeraj
author_facet Chatpalliwar, Vivekanand A.
Porwal, Pawan K.
Upmanyu, Neeraj
author_sort Chatpalliwar, Vivekanand A.
collection PubMed
description A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide, Imp-A, Imp-B, Imp-D, Imp-E, and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house. Efficient chromatographic separation was achieved on a Hypersil BDS C(18) (150 mm×4.6 mm, 5.0 μm) with mobile phase containing 0.2% Triethylamine (TEA) in gradient combination with acetonitrile (ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm. In the developed method, the resolution of DTZ from any pair of impurities was found to be greater than 2.0. The test solution and related substances were found to be stable in the diluent for 24 h. The developed method resolved the drug from its known impurities, stated above, and also from additional impurities generated when the formulation was subjected to forced degradation; the mass balance was found close to 99.9%. Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities. The LOD for DTZ and the known impurities was at a level below 0.02%. The method has shown good, consistent recoveries for DTZ (99.8–101.2%) and also for its six known impurities (97.2–101.3%). The method was found to be accurate, precise, linear, specific, sensitive, rugged, robust, and stability-indicating.
format Online
Article
Text
id pubmed-5760901
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Xi'an Jiaotong University
record_format MEDLINE/PubMed
spelling pubmed-57609012018-02-05 Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation Chatpalliwar, Vivekanand A. Porwal, Pawan K. Upmanyu, Neeraj J Pharm Anal Article A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide, Imp-A, Imp-B, Imp-D, Imp-E, and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house. Efficient chromatographic separation was achieved on a Hypersil BDS C(18) (150 mm×4.6 mm, 5.0 μm) with mobile phase containing 0.2% Triethylamine (TEA) in gradient combination with acetonitrile (ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm. In the developed method, the resolution of DTZ from any pair of impurities was found to be greater than 2.0. The test solution and related substances were found to be stable in the diluent for 24 h. The developed method resolved the drug from its known impurities, stated above, and also from additional impurities generated when the formulation was subjected to forced degradation; the mass balance was found close to 99.9%. Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities. The LOD for DTZ and the known impurities was at a level below 0.02%. The method has shown good, consistent recoveries for DTZ (99.8–101.2%) and also for its six known impurities (97.2–101.3%). The method was found to be accurate, precise, linear, specific, sensitive, rugged, robust, and stability-indicating. Xi'an Jiaotong University 2012-06 2012-02-04 /pmc/articles/PMC5760901/ /pubmed/29403747 http://dx.doi.org/10.1016/j.jpha.2012.01.003 Text en © 2012 Xi'an Jiaotong University http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Chatpalliwar, Vivekanand A.
Porwal, Pawan K.
Upmanyu, Neeraj
Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title_full Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title_fullStr Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title_full_unstemmed Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title_short Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation
title_sort validated gradient stability indicating hplc method for determining diltiazem hydrochloride and related substances in bulk drug and novel tablet formulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760901/
https://www.ncbi.nlm.nih.gov/pubmed/29403747
http://dx.doi.org/10.1016/j.jpha.2012.01.003
work_keys_str_mv AT chatpalliwarvivekananda validatedgradientstabilityindicatinghplcmethodfordeterminingdiltiazemhydrochlorideandrelatedsubstancesinbulkdrugandnoveltabletformulation
AT porwalpawank validatedgradientstabilityindicatinghplcmethodfordeterminingdiltiazemhydrochlorideandrelatedsubstancesinbulkdrugandnoveltabletformulation
AT upmanyuneeraj validatedgradientstabilityindicatinghplcmethodfordeterminingdiltiazemhydrochlorideandrelatedsubstancesinbulkdrugandnoveltabletformulation